3.1.ADC Process

3.1.ADC Process

(1)ADC

-Enter Service Mode by pushing "ADJ" key,

-Enter Internal ADC mode by pushing "►" key at "7. ADC Calibration".

 

EZ ADJUST

ADC Calibration

0.

Tool Option1

ADC Comp 480i

NG

1.

Tool Option2

ADC Comp 1080p

NG

2.

Tool Option3

ADC RGB

NG

3.

Tool Option4

 

 

4.

Tool Option 5

Start

Reset

5.Country Group

6.Area Option

7. ADC Calibration

8.White Balance

9.10 Point WB

10.Test Pattern

11.EDID D/L

12.Sub B/C

13.Touch Sensitivity Setting

<Caution> Using "P-ONLY" key of the Adjustment remote control, power on TV.

If there is no Component Input, disappear “ADC Comp” message.

* ADC Calibration Protocol (RS232)

NO

Item

CMD 1

CMD 2

Data 0

 

 

 

 

 

 

 

 

Enter

Adjust

A

A

0

0

When transfer the ‘Mode In’,

Adjust MODE

‘Mode In’

Carry the command.

 

 

 

 

ADC adjust

ADC Adjust

A

D

1

0

Automatically adjustment

(The use of a internal pattern)

 

 

 

 

 

 

Adjust Sequence

aa 00 00 [Enter Adjust Mode]

xb 00 40 [Component1 Input (480i)]

ad 00 10 [Adjust 480i Comp1]

xb 00 60 [RGB Input (1024*768)] (only LD21B)

ad 00 10 [Adjust 1024*768 RGB] (only LD21B)

aa 00 90 End Adjust mode

* Required equipment : Adjustment remote control.

4. Total Assembly line process

4.1. Adjustment Preparation

▪ W/B Equipment condition CA210

: CCFL/EEFL -> CH9, Test signal: Inner pattern(80IRE) LED -> CH14, Test signal: Inner pattern(80IRE)

▪ Above 5 minutes H/run in the inner pattern. (“power on” key of adjust remote control)

Mode

Temp

Coordinate spec

Target

 

Cool

13,000k

X=0.269 (±0.002)

X=0.271

<Test Signal>

 

 

Y=0.273 (±0.002)

Y=0.276

Inner pattern

 

 

X=0.285 (±0.002)

X=0.287

Medium

9,300k

(204gray,

Y=0.293 (±0.002)

Y=0.296

 

 

80IRE)

Warm

6,500k

X=0.313 (±0.002)

X=0.315

 

Y=0.329 (±0.002)

Y=0.332

 

 

 

 

▪ Edge LED W/B Table in process of aging time (Only LGD Edge LED Module except AUO, CMI, IPS Module)

CA210 : CH 14, Test signal : Inner pattern (80IRE)

 

Aging

 

Cool

Medium

Warm

GP4

time

X

 

y

x

y

x

y

 

(Min)

269

 

273

285

293

313

329

1

0-2

280

 

287

296

307

320

337

2

3-5

279

 

285

295

305

319

335

3

6-9

277

 

284

293

304

317

334

4

10-19

276

 

283

292

303

316

333

5

20-35

274

 

280

290

300

314

330

6

36-49

272

 

277

288

297

312

327

7

50-79

271

 

275

287

295

311

325

8

80-149

270

 

274

286

294

310

324

9

Over 150

269

 

273

285

293

309

323

*Connecting picture of the measuring instrument (On Automatic control)

Inside PATTERN is used when W/B is controlled. Connect to auto controller or push Adjustment R/C POWER ON → Enter the mode of White-Balance, the pattern will come out.

3.2. Function Check

3.2.1. Check display and sound

Check Input and Signal items. (cf. work instructions)

1.TV

2.AV

3.COMPONENT (480i)

4.RGB (PC : 1024 x 768 @ 60hz)

5.HDMI

6.PC Audio In

* Display and Sound check is executed by Remote controller

Caution : Not to push the INSTOP KEY after completion if the function inspection.

Full White Pattern

CA-210

 

 

COLOR

ANALYZER

TYPE : CA-210

RS-232C Communication

*Auto-control interface and directions

(1)Adjust in the place where the influx of light like floodlight around is blocked. (illumination is less than 10 lux).

(2)Adhere closely the Color analyzer(CA210) to the module less than 10 cm distance, keep it with the surface of the Module and Color analyzer's prove vertically.(80° ~ 100°).

(3)Aging time

-After aging start, keep the power on (no suspension of power supply) and heat-run over 5 minutes.

-Using 'no signal' or 'POWER ONLY' or the others, check the back light on.

Copyright ©

LG Electronics. Inc. All rights reserved.

- 10 -

LGE Internal Use Only

Only for training and service purposes

 

 

Page 10
Image 10