Installation of Unit

FormthePiping

1.Wrap the connecting portion of indoor unit with the insulation material and secure it with two Plastic Bands. (for the right piping)

If you connect an additional drain hose, the end of the drain-outlet should be kept distance from the ground. (Do not dip it into water, and fix it on the wall to avoid swinging in the wind.)

In case of the outdoor unit is installed below position of the indoor unit.

2.Tape the Piping, and Connecting Cable from down to up.

3.Form the piping gathered by taping along the exterior wall and fix it onto the wall by saddle or equivalent.

In case of the outdoor unit is installed upper position of the indoor unit.

1.Tape the piping and connecting cable from down to up.

2.In order to prevent water from entering the room, form a trap and tape the piping.

3.Fix the piping onto the wall with saddle or bracket.

Drain water treatment of outdoor unit(Heat Pump Only)

1. When using the drain elbow hose, use a mount of 3cm of higher.

2.In the cold district (0°c(32°F) continued for 2~3 day), the drain water is frozen and the fan fail to function, do not use the drain elbow.

Gas side

piping

Main cable

Tube PE

Foam

Connecting

Cable

Connecting

Cable

(For heater)

Trap is required to prevent the electrical parts

from entering the water.

Seal a small opening around the piping with gum type sealer.

Trap

Drain elbow

Hose(inner diameter ø20)

Arrange the hose downward slope without waving.

18Floor Standing type Air Conditioner

Page 19
Image 19