Installation of Unit
FormthePiping
1.Wrap the connecting portion of indoor unit with the insulation material and secure it with two Plastic Bands. (for the right piping)
•If you connect an additional drain hose, the end of the
In case of the outdoor unit is installed below position of the indoor unit.
2.Tape the Piping, and Connecting Cable from down to up.
3.Form the piping gathered by taping along the exterior wall and fix it onto the wall by saddle or equivalent.
In case of the outdoor unit is installed upper position of the indoor unit.
1.Tape the piping and connecting cable from down to up.
2.In order to prevent water from entering the room, form a trap and tape the piping.
3.Fix the piping onto the wall with saddle or bracket.
Drain water treatment of outdoor unit(Heat Pump Only)
1. When using the drain elbow hose, use a mount of 3cm of higher.
2.In the cold district (0°c(32°F) continued for 2~3 day), the drain water is frozen and the fan fail to function, do not use the drain elbow.
Gas side |
piping |
Main cable |
Tube PE |
Foam |
Connecting |
Cable |
Connecting |
Cable |
(For heater) |
Trap is required to prevent the electrical parts |
from entering the water. |
Seal a small opening around the piping with gum type sealer.
Trap
Drain elbow
Hose(inner diameter ø20)
Arrange the hose downward slope without waving.
18Floor Standing type Air Conditioner