ENGLISH

28EXTERNAL CONTROL DEVICE SETUP

RS-232C configurations

7-Wire Configuration

(Serial female-female NULL modem cable)

 

 

PC

TV

 

RXD

2

 

 

3

TXD

 

 

TXD

3

 

 

2

RXD

 

 

GND

5

 

 

5

GND

 

 

DTR

4

 

 

6

DSR

 

 

DSR

6

 

 

4

DTR

 

 

RTS

7

 

 

8

CTS

 

 

CTS

8

 

 

7

RTS

 

 

 

D-Sub 9

D-Sub 9

 

3-Wire Configurations(Not standard)

 

 

 

PC

TV

 

RXD

2

 

 

3

TXD

 

 

TXD

3

 

 

2

RXD

 

 

GND

5

 

 

5

GND

 

 

DTR

4

 

6

DSR

DSR

6

 

4

DTR

RTS

7

 

8

CTS

CTS

8

 

7

RTS

 

D-Sub 9

D-Sub 9

 

Set ID

Set ID number.

 

 

 

OPTION

Move

OK

 

 

 

 

 

 

 

 

 

• Language

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Caption

: Off

 

 

 

 

• Standby Light

: On

 

 

 

 

• My Media Setting

 

 

 

 

 

• Initial Setting

 

 

 

 

 

• Set ID

: 1

 

 

 

• Mode Setting

: Home Use

 

 

 

 

 

 

 

1Press Home or MENU to access the main menus.

2Press the Navigation buttons to scroll to option and press OK/ENTER.

3Press the Navigation buttons to scroll to Set ID and press OK/ENTER.

4Scroll left or right to select a set ID number and select close. The adjustment range is 1-99.

5When you are finished, press exit.

*Real data mapping 0 : Step 0

A : Step 10 (SET ID 10)

F : Step 15 (SET ID 15)

10 : Step 16 (SET ID 16)

63 : Step 99 (SET ID 99)

64 : Step 100