7. TROUBLE SHOOTING

7-1.BEFORE SVC CHECKING

Be careful of electric shock or disconnecting the parts while trouble shooting.

Voltage of each terminal in 220-240V~ and DC while applying an electric current.

7-2.QC TEST MODE.

Pressing Rinse, and Spin button simultaneously.

Press the Power button, while the above condition.

Press the Start/Pause button as follows.

Number of times the

Check Point

Display Status

Start/Pause button is pressed

 

 

None

Turns on all lamps and locks the door.

 

 

 

 

1 time

Tumble clockwise.

rpm (40~50)

 

 

 

2 times

Low speed Spin.

rpm (600~650)

 

 

 

3 times

High speed Spin.

rpm (1300~1350)

 

 

 

4 times

Inlet valve for prewash turns on.

Water level frequency (25~65)

 

 

 

5 times

Inlet valve for main wash turns on.

Water level frequency (25~65)

 

 

 

6 times

Inlet valve for hot water turns on.

Water level frequency (25~65)

 

 

 

7 times

Inlet valve for dry water turns on.

Water level frequency (25~65)

 

 

 

8 times

Tumble counterclockwise.

rpm (40~50)

 

 

 

9 times

Heater turns on for 3 sec.

Water temperature

 

 

 

10 times

Circulation pump turns on.

Water level frequency (25~65)

 

 

 

11 times

Drain pump turns on.

Water level frequency (25~65)

 

 

 

12 times

Power off and unlock the door.

Turn off all lamps.

 

 

 

7-3.HOW TO KNOW THE WATER LEVEL FREQUENCY

Press the Rinse and Spin button simultaneously.

The digits means water level frequency(10-1kHz)

ex) 241 : Water level frequency = 241× 10-1kHz =24.1 kHz

7-4.HOW TO KNOW TO TEMPERATURE OF EACH THERMISTOR AT OPERATING CONDITION.

Thermistor in tub : Press the [Temp.] button.

Thermistor in dry duct : Press the [Dry] button.

Thermistor in condensing duct : Press the [Intensive] and [Spin] button simultaneously.

13

Page 14
Image 14