8-2.FAULT DIAGNOSIS AND TROUBLE SHOOTING

CAUTION

1.Be careful of electric shock or disconnecting the parts while trouble shooting.

2.First of all, check the connection of each part terminal with wiring diagram.

3.If you replace the MAIN PWB ASSEMBLY, Put in the connectors correctly.

<PWB ASSEMBLY (MAIN)>

<PWB ASSEMBLY (MAIN)>

NO POWER

When measuring the voltage of the outlet, is the voltage AC 220-240V~?

YES

Is the led(1) on?

YES

Is connector(2) disconnected or disassembled?

NO

NO

NO

YES

Check the fuse?

Replace MAIN PWB ASSEMBLY

Reconnect the PWB ASSEMBLY

Is wire of the PWB ASSEMBLY disconnected?

YES

 

NO

Replace PWB ASSEMBLY

Reconnect the PWB ASSEMBLY

19