PREPARING THE INSTALLATION LOCATION

INSTALLATION INSTRUCTIONS

PREPARING THE INSTALLATION LOCATION

IMPORTANT INSTALLATION INFORMATION

All electric cooktops run off a single phase, three-wire or four-wire cable, 240/208 volt, 60 hertz, AC-only electrical supply with ground.

Minimum distance between cooktop and overhead cabinetry is 30 (76.2 cm).

** Do not obstruct these areas!

30” Min.

(76.2 cm)

4" X 8" (10.2 cm x 20.3 cm) opening to route armored cable if panel is present.

All dimensions are stated in inches and millimeters (mm).

Allow 2 (5 cm) space below the armored cable opening to clear the electric cable and allow space for installation of the junction box on the wall at the back of the cooktop.