LG Electronics LCE30845 service manual Installation Instructions, Disconnect the power supply

Models: LCE30845

1 48
Download 48 pages 47.78 Kb
Page 14
Image 14
Electrical ground is required on this appliance.
3-WIRE GROUNDED JUNCTION BOX
Cable from power supply

INSTALLATION INSTRUCTIONS

Electrical ground is required on this appliance.

This appliance is manufactured with a supply wire and a frame connected green or bare copper grounding wire.

NOTE TO ELECTRICIAN: The armored cable leads supplied with the appliance are UL-listed for connection to larger gauge household wiring. The insulation of the leads is rated at temperatures much higher than the temperature rating of household wiring. The current- carrying capacity of the conductor wire is governed by the temperature rating of the insulation around the wire, rather than the wire gauge alone.

 Disconnect the power supply. WARNING: DO NOT ground to a gas supply pipe. DO NOT connect to electrical power supply until appliance is permanently grounded. Connect the ground wire before turning on the power.

Manual background WARNING: This appliance is equipped with a copper conductor flexible cable. If connection is made to aluminum house wiring, use only special connectors which are approved for joining copper and aluminum wires in accordance with the National Electrical Code and local codes and ordinances. Improper connection of aluminum house wiring to copper leads can result in a short circuit or fire. Follow the connector manufacturer’s recommended procedure closely.

WHERE LOCAL CODES PERMIT CONNECTING THE APPLIANCE-GROUNDING CONDUCTOR TO THE NEUTRAL (WHITE) WIRE

Observe all governing codes and local ordinances.

Manual background Disconnect the power supply.

At the circuit breaker box, fuse box or junction

White wire

 

box, connect appliance and power supply cable

(neutral)

 

Red

 

wires as shown.

 

wires

Black

WARNING: You may not ground the cooktop

 

wires

 

 

through the neutral (white) wire if

 

 

cooktop is used in a new branch

 

Junction box

circuit installation (1996 NEC),

 

 

 

mobile home, recreational vehicle,

 

UL-listed conduit

or where local codes do not permit

Green wire (ground)

connector

 

grounding to the neutral (white)

Cable from cooktop

 

wire. When grounding to the neutral

 

 

(white) wire is prohibited, you must use a 4-wire power supply cable. Failure to heed this warning may result in electrocution or other serious personal injury.

Copyright © 2007 LG Electronics. Inc. All right reserved.

- 14 -

LGE Internal Use Only

Only for training and service purposes

 

 

Page 14
Image 14