LG Electronics LCE3081ST Preparing The Installation Location, Important Installation Information

Models: LCE3081ST LCE3681ST

1 34
Download 34 pages 13.71 Kb
Page 21
Image 21
 PREPARING THE INSTALLATION LOCATION

IMPORTANT INSTALLATION INFORMATION PREPARING THE INSTALLATION LOCATION

IMPORTANT INSTALLATION INFORMATION

All electric cooktops run off a single phase, three- wire or four-wire cable, 240/208 volt, 60 hertz, AC-only electrical supply with ground.

Minimum distance between cooktop and overhead cabinetry is 30(762 mm).

Make sure the cabinets and wall coverings around the cooktop can withstand the temperatures (up to 93˚C [200˚F]) generated by the cooktop.

ENGLISH

￿ Manual background

 

 

 

 

 

 

** Do not obstruct these areas!

 

 

 

 

30Min￿.

￿

 

 

￿30 inch Radiant Cooktop￿

￿

￿

 

 

(762 mm)

 

 

 

 

 

 

 

 

 

 

 

￿

￿

 

￿

 

 

 

￿

4" X 8" (102 mm x 203 mm)￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

opening to route armored

 

 

 

 

 

 

 

 

 

cable if panel is present.

LCE3081ST Radiant Cooktop

 

 

 

 

 

 

 

 

Unit

A

B

C

D

E

F

G

H

I

J

K

L

Min

Min

Max

Min

 

 

 

 

 

 

 

 

 

Inch

30-27/32

21-1/2 3-3/4

28-13/16 19-5/8 29-3/8

20-1/4

13/16

13

5-23/32 2-1/2

24

mm

783

546

95

732

498

746

515

20

330

145

64

610

All dimensions are stated in inches and millimeters (mm).

Allow 2(50 mm) space below the armored cable opening to clear the electric cable and allow space for installation of the junction box on the wall at the back of the cooktop.