LG Electronics LCN240CP service manual Troubleshooting CH04

Models: LCN240CP

1 61
Download 61 pages 31.01 Kb
Page 41
Image 41

Troubleshooting Guide

TroubleshootingCH04

Display

Title

Cause of error

Check point & Normal condition

code

 

 

 

 

 

 

 

 

 

 

• The connection of wire(Drain pump/ Float switch)

04

Drain pump

• Float switch Open.

• Drain pump power input. (220V)

/ Float switch

(Normal : short)

• Drain tube installation.

 

 

 

 

• Indoor unit installation. (Inclination)

 

 

 

 

CN Float

0

Check the resistance

Check Point

1.Check the wire connection. (Open, Soldered poorly) Repair the connection or change the PCB.

2.Check the resistance of float switch (Abnormal : Open, Normal : short) Check the float switch.

3.Check the level of water

4.Check the volt. Of Drain pump power supply. (AC 230V) Repair or Change the main PCB.

Service Manual 41

Page 41
Image 41