10. Capacity Table

Heat Pump

10.5A2UH146FA0 [Cooling Capacity]

Combination

 

Outdoor

 

 

 

 

 

 

Indoor Air Temp.: °CWB

 

 

 

 

 

 

 

 

14

 

16

 

18

 

19

 

22

 

24

Capacity Index

 

Air Temp.:

 

 

 

 

 

 

 

TC

 

PI

TC

 

PI

TC

 

PI

TC

 

PI

TC

 

PI

TC

 

PI

(kBtu/h)

 

°CDB

 

 

 

 

 

 

 

kW

 

kW

kW

 

kW

kW

 

kW

kW

 

kW

kW

 

kW

kW

 

kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21

2.63

 

0.92

2.81

 

0.94

2.93

 

0.95

3.04

 

0.97

3.18

 

0.98

3.26

 

1.00

7

 

24

2.59

 

1.01

2.77

 

1.03

2.89

 

1.04

2.99

 

1.06

3.14

 

1.08

3.21

 

1.09

 

29

2.50

 

1.16

2.67

 

1.18

2.79

 

1.20

2.88

 

1.22

3.02

 

1.24

3.09

 

1.25

 

 

35

2.38

 

1.29

2.55

 

1.31

2.66

 

1.33

2.75

 

1.35

2.89

 

1.37

2.95

 

1.39

 

 

41

2.26

 

1.38

2.42

 

1.40

2.52

 

1.42

2.61

 

1.45

2.73

 

1.47

2.80

 

1.48

 

 

46

2.11

 

1.46

2.26

 

1.48

2.35

 

1.50

2.44

 

1.53

2.55

 

1.55

2.61

 

1.57

 

21

4.03

 

0.99

4.31

 

1.01

4.49

 

1.02

4.65

 

1.04

4.87

 

1.06

4.99

 

1.07

7+7

 

24

3.97

 

1.09

4.25

 

1.11

4.43

 

1.12

4.58

 

1.14

4.81

 

1.16

4.92

 

1.17

 

29

3.82

 

1.25

4.10

 

1.27

4.27

 

1.29

4.42

 

1.31

4.63

 

1.33

4.74

 

1.35

 

 

35

3.65

 

1.38

3.91

 

1.41

4.08

 

1.42

4.22

 

1.45

4.42

 

1.47

4.53

 

1.49

 

 

41

3.46

 

1.48

3.70

 

1.50

3.86

 

1.52

3.99

 

1.55

4.19

 

1.57

4.28

 

1.59

 

 

46

3.23

 

1.56

3.46

 

1.59

3.60

 

1.61

3.73

 

1.64

3.91

 

1.66

4.00

 

1.68

Notes:

 

1. Capacities are based on the following conditions.

2. TC : Total Capacity (kW)

Corresponding refrigerant piping length : 7.5m

PI : Power Input (kW)

Level difference : 0m

 

[Heating Capacity]

Combination

 

Indoor

 

 

 

 

 

 

Outdoor Air Temp.: °CWB

 

 

 

 

 

 

 

 

-10

 

-5

 

0

 

6

 

10

 

15

Capacity Index

 

Air Temp.:

 

 

 

 

 

 

 

TC

 

PI

TC

 

PI

TC

 

PI

TC

 

PI

TC

 

PI

TC

 

PI

(kBtu/h)

 

°CDB

 

 

 

 

 

 

 

kW

 

kW

kW

 

kW

kW

 

kW

kW

 

kW

kW

 

kW

kW

 

kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

1.98

 

1.09

2.33

 

1.20

2.70

 

1.30

3.14

 

1.41

3.39

 

1.48

3.75

 

1.59

7

 

18

1.92

 

1.13

2.26

 

1.24

2.61

 

1.35

3.04

 

1.45

3.29

 

1.53

3.63

 

1.64

 

20

1.86

 

1.17

2.19

 

1.28

2.53

 

1.39

2.93

 

1.50

3.19

 

1.58

3.52

 

1.69

 

 

22

1.79

 

1.21

2.11

 

1.32

2.44

 

1.43

2.84

 

1.55

3.07

 

1.63

3.39

 

1.75

 

 

24

1.73

 

1.24

2.04

 

1.36

2.36

 

1.48

2.74

 

1.60

2.97

 

1.68

3.28

 

1.80

 

16

2.89

 

0.95

3.40

 

1.04

3.94

 

1.13

4.58

 

1.22

4.96

 

1.28

5.47

 

1.37

7+7

 

18

2.80

 

0.98

3.30

 

1.07

3.81

 

1.17

4.43

 

1.26

4.80

 

1.33

5.30

 

1.42

 

20

2.71

 

1.01

3.20

 

1.11

3.70

 

1.20

4.28

 

1.30

4.66

 

1.37

5.14

 

1.47

 

 

22

2.62

 

1.04

3.08

 

1.14

3.57

 

1.24

4.15

 

1.34

4.49

 

1.41

4.95

 

1.51

 

 

24

2.53

 

1.08

2.98

 

1.18

3.44

 

1.28

4.00

 

1.38

4.33

 

1.46

4.78

 

1.56

Notes:

 

1. Capacities are based on the following conditions.

2. TC : Total Capacity (kW)

Corresponding refrigerant piping length : 7.5m

PI : Power Input (kW)

Level difference : 0m

 

54MPS Variable Multi Split System(50Hz, R410A)

Page 55
Image 55
LG Electronics LM50 2004-E1 manual Heat Pump, Heating Capacity