14. Installation

14.1 Piping Length & Refrigerant Charge

The maximun allowable level and piping length

[Outdoor Unit]

7.5m

 

It does not matter which unit is higher.

A

Indoor Unit

 

B

 

C

7.5m

D

Model

Standard Length

Max piping length each indoor unit

 

Max total

[Outdoor Unit]

 

 

 

 

 

 

piping length

A, B, C, D

A

B

C

 

D

 

 

 

 

 

 

 

 

A2UC/H146FA0

7.5m

15m

15m

-

 

-

30m(A+B)

 

 

 

 

 

 

 

 

A2UC/H186FA0

7.5m

15m

15m

-

 

-

30m(A+B)

 

 

 

 

 

 

 

 

A3UC/H216FA0

7.5m

15m

15m

15m

 

-

45m(A+B+C)

 

 

 

 

 

 

 

 

A4UC/H306FA0

7.5m

15m

15m

15m

 

15m

60m(A+B+C+D)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant Charge

Indoor Unit Capacity

Pipe Size

Rated

Max

Additional

(Btu/h)

Gas

Liquid

Length

Length

Refrigerant

 

 

 

 

 

 

7k, 9k, 12k

3/8"(9.52mm)

1/4"(6.35mm)

7.5m

15m

30g/m

 

 

 

 

 

 

18k, 24k

1/2"(12.7mm)

1/4"(6.35mm)

7.5m

15m

30g/m

 

 

 

 

 

 

 

 

 

 

 

 

Extra refrigerant = (Extended length - Rated length) x Additional refrigerant