Part 3 ELECTRICAL CONNECTIONS

1.Remove the 3 nuts from the terminal block. (Refer to Figure 7.)

Remove the ground screw and washer retain them.

2.Cut the center portion of ground strap as shown Figure 7.

Do not discard any screws.

3.Attach the ground wire with the ground screw and washer.

4.Attach the 3 wires (L1, Neutral, L2) to the correct terminal block bolts. Be certain that the center wire (white/neutral) is connected to the center position of the terminal block. Tighten the 3 nuts securely onto the terminal block.

5.Go to page 8.

3-wire connection: conduit

Install the conduit as follows:

Remove the Conduit connection plate from the rear of drawer body and rotate it as shown in Figure 8. The conduit hole (11/8”) must be used.

First, prepare conduit cord as shown in Figure 9.

3 wire

4 wire

or

FIGURE 9

Second, install conduit cord as shown in Figure 10.

For conduit installations, after purchasing a strain relief, insert it in the conduit hole (11/8”). Then install the conduit cord through the body of strain relief and fasten the strain relief with its ring. Reinstall the bracket.

Remove the Conduit connection plate

FIGURE 8

Assemble the

strain relief hole

FIGURE 10

6

Page 6
Image 6
LG Electronics LRE30755S, LRE30451S installation manual Wire connection conduit, Install the conduit as follows