LG Electronics LRE30451S wire connection conduit, Reinstall the Conduit connection plate

Models: LRE30451S LRE30755S

1 16
Download 16 pages 63.23 Kb
Page 7
Image 7
4-wire connection: conduit

Part 3 ELECTRICAL CONNECTIONS

Third, connect the wires.

If bare wire is used, connect with adapter lugs as shown in Figures 11 and 12.

1.Insert the end of each wire (L1, L2, Neutral) into the each lug. Tighten the clamping screw.

2.Remove the 3 nuts from the terminal block and retain them.

3.Attach the lug with white wire (Neutral) to the center terminal block bolt.

4.Attach the lug with black wire (L2) to the left terminal block bolt.

5.Attach the lug with red wire (L1) to the right terminal block bolt.

6.Tighten 3 nuts (removed earlier) securely onto the terminal block.

7.Go to page 8.

4-wire connection: conduit

1.Follow the instructions under “Install the conduit cord as follows” on page 6 to correctly install the strain relief.

You must install the conduit with a strain relief.

2.Cut the center portion of ground strap as shown Figure 13.

Do not discard any screws.

If bare wire is used, connect with adapter lugs as shown in Figures 11 and 13.

3.Insert the end of green wire (ground) from conduit into the lug and tighten the clamping screw. Attach the lug to the GND hole below terminal block with ground screw (removed earlier).

4.Insert the end of each wire (L1, L2, Neutral) into each separate lug. Tighten the clamping screw.

5.Remove the 3 nuts from the terminal block. Remove the ground screw and retain them.

6.Attach the lug with white wire (Neutral) to the center terminal block bolt.

7.Attach the lug with black wire (L2) to the left terminal block bolt.

8.Attach the lug with red wire (L1) to the right terminal block bolt.

9.Tighten 3 nuts (removed earlier) securely into the terminal block.

10.Go to page 8.

Reinstall the

Conduit connection plate

BARE WIRE TORQUE SPECIFICATIONS LUG ATTACHED TO TERMINAL BLOCK - 20 IN-LB

WIRE AWG

TORQUE

10-14

20

IN-LB

8

25

IN-LB

4-6

35

IN-LB

 

 

 

FIGURE 11

3-wire connection

L2

N

L1

FIGURE 12

4-wire connection

L2

N

L1

 

 

 

G

 

FIGURE 13

7

Page 7
Image 7
LG Electronics LRE30451S, LRE30755S wire connection conduit, You must install the conduit with a strain relief