Set ID

External Control Device Setup

Set ID

-Use this function to specify a monitor ID number.

-Refer to ‘Real Data Mapping 1’. See page 27.

1.Press the MENU button and then use the D / E button to select the SPECIAL menu.

2.Press the G button and then use D / E button to select Set ID..

3.Press the G button and then use F / G button to adjust Set ID. to choose the desired monitor ID number.

• The adjustment range of Set ID. is 1 ~ 99.

Communication Parameters

• Baud rate : 115200 bps (UART)

• Stop bit : 1 bit

• Data length : 8 bits

• Communication code : ASCII code

• Parity : None

 

VIDEO

AUDIO

TIME

SPECIAL

Communication ParametersSCREEN

TWIN

Language

Key lock

ISM Method

Low power

Set ID.

G

OSD Rotate

MENU Prev.

1

Command Reference List

 

COMMAND 1 COMMAND 2

DATA

 

 

 

 

(Hexadecimal)

 

 

 

 

 

01. Power

k

a

0

~ 1

02.

Input Select

k

b

0

~ 4

03. Aspect Ratio

k

c

0

~ 3

04. Screen Mute

k

d

0

~ 1

05. Volume Mute

k

e

0

~ 1

06.

Volume Control

k

f

0

~ 64

07.

Contrast

k

g

0

~ 64

08.

Brightness

k

h

0

~ 64

09.

Color

k

i

0

~ 64

10. Tint

k

j

0

~ 64

11. Sharpness

k

k

0

~ 64

12. OSD Select

k

l

0

~ 1

13.

Remote Control Lock Mode

k

m

0

~ 1

14.

PIP/Twin

k

n

0

~ 3

15.

PIP Aspect Ratio

k

o

0

~ 1

16.

Split Zoom

k

p

21 ~99

17.

PIP Position

k

q

0

~ 3

18. Treble

k

r

0

~ 64

19. Bass

k

s

0

~ 64

20.

Balance

k

t

0

~ 64

21.

Color Temperature

k

u

0

~ 3

22. Red Adjustment

k

v

0

~ C8

23. Green Adjustment

k

w

0

~ C8

24.

Blue Adjustment

k

$

0

~ C8

25.

PIP Input Source

k

y

0

~ 4

26. Abnormal State

k

z

0

~ a

27. ISM Method

j

p

0

~ 3

28. Low Power

j

q

0

~ 1

 

 

 

 

 

 

29.

Orbiter Time Setting

j

r

1

~ FE

30.

Orbiter Pixel Setting

j

s

0

~9

31.

Picture Size Setting

j

t

0

~64

 

for Twin Picture mode

 

 

 

 

32. Auto Configure

j

u

1

 

 

 

 

 

 

 

Menu doesn’t display on screen when setting the 4, 12, 13, and 26 ~ 32.

Transmission / Receiving Protocol

Transmission

[Command1][Command2][ ][Set ID][ ][Data][Cr]

*[Command 1]: k, j

*[Command 2]: To control PDP set.

*[Set ID]: You can adjust the set ID to choose desired moni- tor ID number in Special menu. Adjustment range is 1 ~ 99. When selecting Set ID ‘0’, every con- nected PDP set is controlled. Set ID is indicated as decimal (1~99) on menu and as Hexa decimal (0x0~0x63) on transmission/receiving protocol.

*[DATA]: To transmit command data.

Transmit ‘FF’ data to read status of command.

*[Cr]: Carriage Return ASCII code ‘0x0D’

* [ ]: ASCII code ‘space (0x20)’

OK Acknowledgement

[Command2][ ][Set ID][ ][OK][Data][x]

*The Monitor transmits ACK (acknowledgement) based on this format when receiving normal data. At this time, if the data is data read mode, it indicates present status data. If the data is data write mode, it returns the data of the PC computer.

Error Acknowledgement

[Command2][ ][Set ID][ ][NG][x]

*The Monitor transmits ACK (acknowledgement) based on this format when receiving abnormal data from non-viable functions or communication errors.

Data 1: Illegal Code

2:Not supported function

3:Wait more time

26 Plasma Monitor