Configuration Options via Command Line (Cont.)
(Continued from previous page)
After you specify the Pro:Idiom messages setting, the system will display an overview of the new configuration and prompt for confirmation, for example:
New PID Configuration |
| |
Program PIDs range: | 0x30 - 0x6f | |
Pro:Idiom PIDs | range: | 0x1051 - 0x1058 |
Send Pro:Idiom | messages: | no |
Do you want to save the new configuration? [y/n]:
5.Either:
•Type y and press Enter, to save the new configuration. The system will confirm the configuration update:
New configuration has been saved.
•Type n and press Enter to return to the Setup Command > prompt without saving your changes.
Configure the Control Port
1.At the Setup Command > prompt, type setip and press Enter.
The system displays an overview of the current TCP/IP network configuration followed by the Network Configuration Menu, for example:
Current Network Configuration
Interface controller port
Host name: | oat100r |
Using DHCP: | YES |
DNS servers | 68.94.156.1 |
Primary DNS: | |
Secondary DNS: | 68.94.157.1 |
Network Configuration Menu
ip | Configure | Control Port IP |
dns | Configure | DNS |
exit | Exit network configuration |
Choose item to modify >
(Continued on next page)
52 |