Configuration Options via Command Line (Cont.)

(Continued from previous page)

Available output modes: 1 - RF

2 - IP

Enter number of new output mode [1]>

2.At the prompt, either press Enter to accept the default value (i.e., the current setting) in square brackets, or type the number that corresponds to the appropriate output mode and press Enter.

The system will confirm your selection, for example:

Output mode is set: RF

3.Complete the appropriate configuration, depending on the output mode. Refer to “Configure the RF Output” on page 54 or “Configure the IP Output” on pages 56 to 59, as applicable.

Configure the Program PIDs

If any Pro:Idiom channels are configured in the site’s entertainment system, you must configure program PIDs for the OAT100R output. See “Packet Identifiers (PIDs) Overview” on page 10 for further information, and/or check with your service representative, if necessary.

1.At the Setup Command > prompt, type pid and press Enter.

The system displays an overview of the current PID configuration (including Pro:Idiom PIDs) followed by a prompt for the starting program PID, for example:

Current PID Configuration

 

Program PIDs range:

0x30 - 0x6f

Pro:Idiom PIDs

range:

0x1050 - 0x1057

Send Pro:Idiom

messages:

no

Enter the starting program PID [0x30]:

2.At the prompt, type the new starting program PID in hexadecimal format, and then press Enter.

Note: The system will auto-increment the remaining 63 program PIDs from the starting PID.

Note: If any of the program PIDs conflicts with PIDs that have been set/reserved for Pro:Idiom, the system will display an error message and then return to the starting program PID prompt.

If you change the starting program PID, the system will display an overview of the new configuration and prompt for confirmation, for example:

(Continued on next page)

50

206-4218