Configuration Options via Command Line (Cont.)
(Continued from previous page) |
| |
New PID Configuration |
| |
Program PIDs range: | 0x31 - 0x70 | |
Pro:Idiom PIDs | range: | 0x1050 - 0x1057 |
Send Pro:Idiom | messages: | no |
Do you want to save the new configuration? [y/n]:
3.Either:
•Type y and press Enter, to save the new configuration. The system will confirm the configuration update:
New configuration has been saved.
•Type n and press Enter to return to the Setup Command > prompt without saving your changes.
Configure the Pro:Idiom PIDs
This option enables you to configure Pro:Idiom PIDs and enable/disable Pro:Idiom messages in the output stream. It is intended only for qualified service personnel and should only be used when recommended by LG. This option requires the Pro:Idiom user password. If this is the first time the command is being run, contact LG for the password; otherwise, if necessary, obtain the password from the system administrator.
1.At the Setup Command > prompt, type proidiom and press Enter.
2.At the Enter Pro:Idiom user password: prompt, type the password
The system displays an overview of the current PID configuration (including program PIDs) followed by a prompt for the starting Pro:Idiom PID, for example:
Current PID Configuration |
| |
Program PIDs range: | 0x30 - 0x6f | |
Pro:Idiom PIDs | range: | 0x1050 - 0x1057 |
Send Pro:Idiom | messages: | no |
Enter the starting Pro:Idiom PID [0x1050]:
3.At the prompt, either press Enter to accept the default value (i.e., the current setting) in square brackets, or type the appropriate starting Pro:Idiom PID in hexadecimal format, and then press Enter.
4.At the Insert Pro:Idiom messages in output stream? (y/n) [n]: prompt, either:
•Type y and press Enter to enable Pro:Idiom messages in the output stream, or
•Type n and press Enter to disable Pro:Idiom messages in the output stream.
(Continued on next page)
51 |