DISCONTINUED |
|
|
|
| |
PRODUCT |
|
|
|
| |
| PowerSure™ PSA |
| |||
|
| ||||
WHAT’S IN THE BOX |
| * Power ON/OFF/ | *** USB port | Site Wiring Fault * | |
| Indicator (Red) | ||||
• |
| Alarm Silence |
| ||
PowerSure PSA | * Utility Indicator | *** | DIP switches ** | ||
• PowerSure family user manual on CD (also at www.liebert.com) |
| (Green) |
| ||
| ** Orange output recep- | Data Line *** | |||
• | Warranty card |
| Battery Indicator * | ||
| tacles (battery backup | Protection | |||
• | MultiLink™ software CD |
| (Green/Amber) | and surge protection) | Connectors |
• MultiLink serial cable (M3LS9P9S), 10 ft. (3m) |
|
| (4 receptacles on 350, |
| |
| * Fault Indicator | 500 and 650VA models) |
| ||
• |
| (Red/Green) | ** Black output |
| |
• USB cable, 6 ft. (1.8m) |
|
|
| ||
|
| receptacles (surge | Battery cover plate | ||
|
|
| For details, see : | protection only) | |
For more details, refer to the PowerSure user manual on CD. |
| (on bottom for | |||
| * Controls and Indicators |
| 650&1000VA models) | ||
Para una información más detallada, consulte el manual del usuario |
| ** Installation | (on rear of 350&500VA | ||
de la familia PowerSure en el CD. |
| *** Communications | power cord | models) | |
|
|
INSTALLATION
Read all safety, installation and operating instructions in the PowerSure family user manual on the included CD or at www.liebert.com before operating the UPS. Adhere to all warnings on the unit and in the manual.
1.Install the UPS indoors in a controlled environment, where it cannot be accidentally turned off. Place it in an area of unrestricted airflow around the unit, away from water, flammable liquids, gases, corrosives and conductive contaminants. Maintain a minimum clearance of 4 inches (100mm) on each side of the UPS. Maintain an ambi- ent temperature range of 32°F to 104°F (0°C to 40°C).
2.Plug the PSA’s power cord into an AC outlet. Check the Site Wiring Fault Indicator on the rear; if it is illuminated, refer to the Troubleshooting section.
3.Plug any computers and monitors into the orange receptacles for battery backup and surge protection; other office machines that do not exceed the capacity of the UPS may be plugged into either of the two (2) black receptacles, which provide surge protection only.
4.Connect Phone/Fax/DSL/Internet/Modem devices to data line connectors.
5.Press and release the ON/OFF/Alarm Silence button to turn on the UPS. The UPS will beep and the Utility Indi- cator will illuminate (green).
6.Turn on connected equipment.
Plug computers, monitors & network hubs into orange receptacles
Plug this type of equipment into black receptacles ONLY
Inkjet printers | Scanners | Fax machines |
|
|
|
|
|
CONTROLS AND INDICATORS | COMMUNICATIONS |
This button controls output power to the connected load and has three functions:
•Turns the PowerSure PSA ON
•Turns the PowerSure PSA OFF
•Silences PowerSure PSA alarms
TURN THE UPS ON: Press and release the main ON/OFF button to start the UPS. An audible alarm will sound briefly.
TURN THE UPS OFF: When the PSA is ON, hold the main ON/OFF button down for more than 2 seconds to shut it down. An audible alarm will sound briefly.
SILENCE AN ALARM: When a UPS alarm is active, press and release the main ON/OFF button to silence the audible alarm (Exceptions: low battery, overload and overtemperature). DO NOT hold the button down for more than 2 seconds or the PSA will shut down.
The PowerSure PSA will communicate with your computer in either of two ways: over its
MultiLink supplies useful monitoring data, such as input voltage and battery level, and will perform an orderly shut- down of the computer system. Microsoft Windows XP and 2000 operating system utilities supply UPS status infor- mation and will perform an orderly computer shutdown. Check your computer’s OS features to determine whether it has power management capability.
For MultiLink Serial Communications
•Connect the provided MultiLink serial cable to the
•Install the MultiLink
For USB Communications (with operating system power management)
•Connect the USB cable provided with the UPS to the USB ports on the PSA and your computer. The PSA will work automatically with the
•All USB models are compatible with Microsoft Windows 2000, Windows XP and Macintosh® OS 10.2 or later.
CHECK THE PSA’S CONDITION: Three status indicators on the front of the UPS illuminate to specify the status of the UPS (see Troubleshooting section for details).
Utility Indicator
Green: Normal operation
Amber: Buck/Boost
mode
Fault Indicator |
| |
Green: | Overload/ |
|
| Overtemperature | Battery Indicator |
Red: | UPS fault | Green: On battery |
Amber: Battery warning
SITE WIRING FAULT INDICATOR (RED)
The Site Wiring Fault Indi- | Rear of UPS | |
cator on the rear panel, as | ||
DIP Switches | ||
shown, illuminates red | ||
| ||
when the UPS detects a |
| |
Site Wiring | ||
poor | Fault | |
Troubleshooting Chart if | Indicator | |
indicator is illuminated.) | (Red) | |
|
TRANSFER VOLTAGE SELECTORS (DIP SWITCHES)
The
DIP switch settings
Left | Right | Nominal Utility | Setting |
↑ Up | ↑ Up | 120VAC | 85 - 145VAC (default) |
↑ Up | ↓ Down | 110VAC | 78 - 138VAC |
↓ Down | ↑ Up | 127VAC | 90 - 150VAC |
↓ Down | ↓ Down | 120VAC | 85 - 145VAC |
CAUTION
! Never change the voltage settings while the UPS is ON and powering connected loads. Change DIP switches only when the UPS is OFF.
CAUTION
! To ensure protection of the connected equipment, the DIP switch settings should match the nominal utility input voltage. DIP switch settings not matching the nominal utility could potentially damage connected equipment.
SPECIFICATIONS
Model Number | ||||||
Power Rating VA/W | 350VA/210W |
| 500VA/300W | 650VA/390W | 1000VA/600W | |
DIMENSIONS: in. (mm) |
|
|
|
|
| |
Unit | 4.6x7.7x8.7 |
| 4.6x7.7x8.7 | 4.6x14.1x8.7 | 4.6x14.1x8.7 | |
WxDxH | (116x196x222) |
| (116x196x222) | (116x358x222) | (116x358x222) | |
Shipping | 7.7x12.2x11.5 |
| 7.7x12.2x11.5 | 9.5x19.7x12.4 | 9.5x19.7x12.4 | |
WxDxH | (196x310x293) |
| (196x310x293) | (242x500x316) | (242x500x316) | |
WEIGHT: lbs (kg) |
|
|
|
|
| |
Unit | 16.8 (7.6) |
| 17.2 (7.8) | 20.7 (9.4) | 29.7 (13.5) | |
Shipping | 18.1 (8.2) |
| 18.5 (8.4) | 22.9 (10.4) | 31.9 (14.5) | |
INPUT AC PARAMETERS |
|
|
|
|
| |
Surge Protection |
|
| 570J |
| ||
Voltage Range Without | 78VAC - 150VAC, DIP switch selectable | |||||
Battery Operation |
| (see “DIP switch settings” on page 1) | ||||
Frequency Range |
|
| 46.5 - 63.5 Hz (±0.1 Hz) |
| ||
Input Power Cord | 6 ft. (1.8m) attached, w/ NEMA | |||||
OUTPUT AC PARAMETERS |
|
|
|
| ||
|
|
|
|
| (6) NEMA | |
| (4) NEMA | (orange) Battery | ||||
| backup + surge | |||||
| Battery backup + surge protection; | |||||
Output Receptacles | protection; | |||||
(2) NEMA | ||||||
| (2) NEMA | |||||
|
|
| Surge protection |
| ||
|
|
|
| (black) Surge | ||
|
|
|
|
| protection | |
Voltage (Normal mode) |
|
| Nominal (110, 120, 127VAC) ±10% | |||
Voltage (Battery mode) |
|
| 120VAC ±8% |
| ||
Output Current | 2.9 A |
| 4.2 A | 5.4 A | 8.3 A | |
Waveform (Battery mode) |
|
| Stepped Sinewave |
| ||
Frequency |
|
| 50 Hz or 60 Hz; auto sensing |
| ||
Overload Warning |
| >100% |
| |||
(Normal & Battery modes) |
|
| ||||
|
|
|
|
| ||
Overload Shutdown |
| >110% |
| |||
BATTERY PARAMETERS |
|
|
|
|
| |
Type | ||||||
QuantityxVoltagexRating | (1)x12Vx7Ah |
| (1)x12Vx9Ah | (1)x12Vx9Ah | (2)x12Vx7.5Ah | |
Transfer Time |
|
| 4 - 6 ms typical |
| ||
Backup Time: | At 77°F (25°C), resistive loading, with fully charged batteries: | |||||
Full Load | 8 minutes |
| 8 minutes | 5 minutes | 5 minutes | |
Half Load | 26 minutes |
| 24 minutes | 16 minutes | 18 minutes | |
Recharge Time |
|
| 6 hours to 90% of rated capacity, |
| ||
| after full discharge into resistive load | |||||
|
|
ENVIRONMENTAL (ALL MODELS)
Operating | +32°F to +104°F | |
Temperature | (0°C to +40°C) | |
|
| |
Storage | +5°F to +104°F | |
Temperature | ||
Relative | 0% to 95%, non- | |
Humidity | condensing | |
Operating | Up to 10,000 ft. | |
(3000m) at 86°F (30°C) | ||
Elevation | ||
without derating | ||
| ||
Audible Noise | < 40 dBA, at 1 meter | |
|
| |
AGENCY |
| |
|
| |
Safety | UL 1778, | |
|
| |
| ANSI C62.41, Category | |
Surge | A, Level 3 | |
(IEEE 587, Category A); | ||
| ||
| Criteria A | |
ESD | ||
Criteria A | ||
| ||
Susceptibility | ||
Criteria A | ||
| ||
Electrical Fast | ||
Transient/Burst | Criteria A | |
Emissions | FCC Part 15, Subpart B, | |
Class B | ||
| ||
Conducted | ||
Immunity | Criteria A | |
Harmonics | ||
|
| |
Flicker | ||
|
| |
Transportation | ISTA Procedure 1A | |
|
|