Liebert HiSwitch2 manual Specifications, Frequency 50 or 60 Hz field selectable, +/- 5%, Rating A

Models: HiSwitch2

1 4
Download 4 pages 62.16 Kb
Page 4
Image 4
Technical Features [Liebert Hiswitch2]

Technical Features [Liebert Hiswitch2]

 

Rating (A)

Dimensions (W x D x H)
Weight*(kg)

 

 

[mm]

 

 

 

 

 

 

100

762 x 813 x 1956

354

 

250

762 x 813 x 1956

354

 

400

965 x 813 x 1956

544

 

600

965 x 813 x 1956

544

 

800

2134 x 813 x 1956

1134

 

1000

2134 x 813 x 1956

1134

*Note: Actual Weights will vary depending on installed options.

Specifications

Operating Specifications

Voltage: 208, 220, 240, 380, 400, 415 VAC (field selectable), +/- 10%

Frequency: 50 or 60 Hz (field selectable), +/- 5%

Short-circuit Withstand Capability: 100kA at 208VAC, from 65kA to 100kA at 480VAC (depending on the rating)

Sense and transfer time: 5ms maximum

Overload Capability: 125% for 10 minutes, 150% for 2 minutes, 110% for 1 hour

Operating Temperature: 0 to 40° C

Standard Features

Rating (A) All components front accessible for installation and service; no side or rear access required

Dimensions (W x D x H) Triple-redundant DSP digital logic

Weight*(kg) Dual-redundant power supplies Specifications 100% rated, fuseless design

Operating Specifications Flash memory enables firmware updates while supporting critical load

Voltage: 208, 220, 240, 380, 400, 415 VAC (field selectable), +/- 10% CANBUS internal control wiring

Frequency: 50 or 60 Hz (field selectable), +/- 5% Rack-out control/power assembly on units up to 600A, to allow maintenance, service, or full replacement without disrupting the critical load

Sense and transfer time: 5ms maximum 3-pole configurations

Operating Temperature: 0 to 40° C Top and bottom cable entry

Standard Features Dual-lug installation bus with pem nuts for single-hand installation and "hot" torque service

Optional Features*

 Triple-redundant DSP digital logic Full range of Open Comms™ hardware and software

 Flash memory enables firmware updates while supporting critical load Internal modem for dialing out alarms to phone or pager

 CANBUS internal control wiring Color touch-screen LCD interface eliminates mechanical pushbuttons

 3-pole configurations Intuitive user interface with drop-down menus and dialog boxes

Optional Features* Programmable output relays for custom customer alarms and connections

 Full range of Open Comms™ hardware and software Customizable input relays allow alarms from other devices to be displayed on HiSwitch2 display

*Compatible with LCD Panel only

While every precaution has been taken to ensure accuracy and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. © 2004 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice.

All names referred to are trademarks or registered trademarks of their respective owners. ® Liebert and the Liebert logo are registered trademarks of the Liebert Corporation. ® Keeping Business in Business is a registered trademark of the Liebert Corporation. The Emerson logo is a trademark and service mark of Emerson Electric Co.

Liebert HIROSS UPS Sales Headquarters

Liebert HIROSS Services Headquarters

Emerson Network Power Ltd - UK

Via Leonardo da Vinci,8

Via Leonardo da Vinci,8

Fourth Avenue, Globe Park - Marlow

35028 - Piove di Sacco (PD)

35028 - Piove di Sacco (PD)

Buckinghamshire - SL71YG

tel. +39 049 9719111 fax +39 049 9719317

tel. +39 049 9719111 fax +39 049 9717053

tel. +44 1628 403200 fax +44 1628 403203

 

service@liebert-hiross.com

 

www.liebert-hiross.com

Page 4
Image 4
Liebert HiSwitch2 Specifications, Voltage 208, 220, 240, 380, 400, 415 VAC field selectable, +/- 10%, Rating A, Weight*kg