Decommissioning

uOpen the water connection.

The temperature is not cold enough.

The door of the appliance is not properly closed. u Close the door of the appliance.

Insufficient ventilation.

u

Clear ventilation grilles.

The ambient temperature is too high.

u

Solution: (see 1.2) .

The appliance was opened too frequently or for too long.

uWait until the appliance reaches the required temperature itself. If not, contact the customer service. (see Mainte- nance).

Too much fresh food was placed inside without SuperFrost.

uSolution: (see 5.8)

The temperature is incorrectly set.

uSet the temperature to a colder setting and check after 24 hours.

Theetc).appliance is too close to a source of heat (stove, heater

uChange the position of the appliance or the source of heat.

The appliance was not inserted properly into the recess.

uCheck whether the appliance was inserted correctly and the door closes properly.

8 Decommissioning

8.1 Shut off the water intake*

NOTICE

Malfunction of the water intake!

If the water intake is shut off during operation but the IceMaker remains in operation, the water intake pipe may ice up.

u Switch off the IceMaker if the water supply is interrupted (e.g. holiday).

8.2 Switching off the appliance

u Press On/Off button Fig. 2 (4) for approx. 2 seconds.

w The temperature display is dark.

w If the appliance cannot be switched off, the child lock function is active (see 5.2) .

8.3 Taking the appliance out of service*

uEmpty the appliance.

uPut the IceMaker in the cleaning position (see Mainte- nance).

uPull out the power plug.

uClean the appliance (see 6.2) .

uLeave the door open to prevent odour.

9 Disposing of the appliance

The appliance contains some reusable materials and should be disposed of properly - not simply with unsorted household refuse. Appliances which are no longer needed must be disposed of in a professional and appropriate way, in accordance with the current local regulations and laws.

When disposing of the appliance, ensure that the refrigeration circuit is not damaged to prevent uncontrolled escape of the refrigerant it contains (data on type plate) and oil.

u Disable the appliance.

uPull out the plug.

uCut through the connecting cable.

10

* Depending on model and options

Page 10
Image 10