Lifebreath 1000RHC Speed Selection and Controls, Air Conditioning DX Coil, Hydronic Reheat Coil

Models: 1200DDPOOL 700DDPOOL 1000RHCAC 1000RHC

1 26
Download 26 pages 29.72 Kb
Page 19
Image 19
Speed Selection and Controls

Speed Selection and Controls

These recirculation models are equipped with a 3 speed control, low medium and high, (Note - 1000RHC/RHCAC must be set to high speed when air conditioning is required), as well as a lighted on/off switch and a low voltage terminal strip. The low voltage terminal strip is used to connect the supplied dehumidistat.

Air Conditioning (DX) Coil

Model 1000RHCAC Only

The Direct Expansion (DX) Coil located inside the cabi- net is designed to dehumidify the incoming fresh air from the outside and is not intended as an air condition- ing unit for the space. The coil must be connected to an outdoor condensing unit, (this unit or it’s controls are not provided by NUTECH). Special care and atten- tion should be given to ensure the Model 1000RHCAC is set to high speed during air condi- tioning mode, to avoid the coil from freezing up.

DEHUMIDISTAT

END OF UNIT

not used

ON/OFF SWITCH

3 SPEED CONTROL

 

 

idistat

Dehum

tive to

Setting

Rela

 

ions

Outside

Condit

 

WINTER

:

 

Set

dehumidistat

 

30%

to 40%.

een

 

dry,

betw

 

e is too

If hom

 

 

setting.

adjust to higher

id,

If home is too hum .

adjust to

lower setting

 

SUMMER

 

 

 

idistat

Set dehum

 

 

 

to OFF.

 

 

HIGH

COMMON

* NOTE: The external low voltage contacts on a pool

PART NO. 99-130W

unit control the Ventilation/Recirculation

Damper only, not low/high speed control.

•Provides ventilation or recirculation mode

 

Hydronic Reheat Coil

Model 1000RHC and 1000RHCAC

DISCLAIMER

The coil is designed to temper the air delivered through the HRV, to room temperature and is not a heating appliance for the space.

Special care and attention should be given to selecting a thermostat which will be connected to the pump feeding the coil. The thermostats function will be to signal the pump to send water through the system if temperatures drop below 40˚F (5˚C) to prevent the coil from freezing and also to shut the pump off if the air temperature leaving the coil exceeds 77˚F (25˚C) to prevent over heating motors.

Thermostats and pumps not available from NUTECH.

The Model 1000RHC and RHCAC is intended to be installed by certified HVAC trades people. Damage resulting in partial or complete failure of the Reheat/Air Conditioning portion is the respon- sibility of the installing contractor. Precautions should be put into place to avoid these coils from freezing or causing the motors to overheat or any other unforeseen problem not mentioned here.

The DX Coil is supplied with an orificing device suitable for 1.5 tons of air conditioning @ 95˚F 80% RH inlet air.

19

Page 19
Image 19
Lifebreath Speed Selection and Controls, Air Conditioning DX Coil, Hydronic Reheat Coil, Model 1000RHCAC Only