Lifebreath 1200DDPOOL Model 1000RHC and Model 1000RHCAC, Specifications, Performance, Warranty

Models: 1200DDPOOL 700DDPOOL 1000RHCAC 1000RHC

1 26
Download 26 pages 29.72 Kb
Page 5
Image 5
DIMENSIONS 1000RHC/RHCAC mm (inches)
WEIGHT
99-101
99-130

SPECIFICATIONS

CORES

Modular (3 section) patented aluminum heat recovery cores arranged for high efficiency cross-flow ventilation. Meets the flame spread and smoke developed classifications of the National Building Code and NFPA 90A (1993 Edition).

MOTORS

Two PSC, 3 speed double shafted, 120 VAC, 3.95 Amps each (7.9 total on high speed). HP - 1/4, 1625 RPM. Watts - total on high speed - 848.

FILTERS Washable air filters in exhaust and supply air streams.

BLOWERS

Each air stream has one double shafted motor driving 2 centrifugal blowers.

HYDRONIC REHEAT COIL

Standard built-in coil in both 1000RHC and 1000RHCAC. Rated 35,000 BTU

@140°F, 3 US gal./min. Design temperature drop is 20°F, fluid pressure drop is 1.3 feet WG at rated flow, 3/4" fittings.

CONNECTION DUCT SIZES Five - 20" X 8" H (508 mm x 200 mm H).

DIRECT EXPANSION (DX) EVAPORATOR COIL (model 1000RHCAC only) Factory installed 1.5 ton DX coil, 0.875" OD suction side, 0.625" OD liquid side, built-in orifice.

MOUNTING

Two brackets under cabinet, connect to threaded rod type supports (not included).

CASE

20 gauge prepainted galvanized steel (G60) for superior corrosion resistance. Insulated with foil faced insulation where required to prevent exterior conden- sation. Drain connections; two - 1/2" (12 mm) O.D.

CONTROLS

Illuminated power switch, 3 speed blower control, low voltage (24 VAC) termi- nals to connect remote controls (not included), defrost light indicating defrost/recirculation mode.

DEFROST CONTROLS

Supply bypass damper routes indoor air to defrost core.

255 lbs.(116 Kg) SHIPPING WEIGHT 280 lbs.(127 Kg)

DIMENSIONS 1000RHC/RHCAC mm (inches)

Model 1000RHC and

Model 1000RHCAC

PERFORMANCE

AIRFLOWS (Each Air Stream)

L/s (CFM)

613 (1300)

 

 

 

 

 

 

 

VAC

 

 

 

 

 

 

 

(AMPS) @ 120

566 (1200)

 

 

 

 

 

 

8.1 HIGH

518 (1100)

 

 

 

 

 

 

 

472 (1000)

 

 

 

 

HIGH SPEED

7.8 MED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIRFLOW

423 (900)

 

 

 

 

 

 

 

CURRENT DRAW

378 (800)

 

 

 

 

 

 

7.1 LOW

 

 

 

 

 

 

 

329 (700)

 

 

 

 

 

 

 

282 (600)

 

 

 

 

 

 

 

235 (500)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOTAL

 

25 (.1)

50 (.2)

75 (.3)

100 (.4)

125 (.5)

150 (.6)

175 (.7)

200 (.8)

 

 

EXTERNAL STATIC PRESSURE IN PASCALS (in. W.C.)

TEMPERATURE EFFECTIVENESS

EFFECTIVENESS

50%

 

70%

 

60%

NOTE: Exhaust Relative Humidity (RH) at 40%

235

282

329

378

423

472

518

566

(500) (600) (700) (800) (900) (1000) (1100) (1200)

AIRFLOW IN L/s (CFM)

Performance data includes both reheat and DX coil installed. Note there is little change in air flow with the DX coil removed.

DEFROST &

 

 

 

 

SUPPLY AIR

EXHAUST AIR

 

 

FROM OUTSIDE

RECIRCULATION

 

 

 

 

 

 

 

 

TO OUTSIDE

AIR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Service clearance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

is 760 mm (30 in.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXHAUST AIR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FROM BUILDING

 

 

1088 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

DRAIN CONNECTION

SUPPLY AIR

 

 

 

(46 3/4")

 

 

 

 

 

 

TO BUILDING

FRONT VIEW

CONTROLS

508 mm

(20")

263 mm

(10 3/8 ")

200 mm

(8")

 

1055 mm

COIL FITTINGS

(41 1/2")

DISCHARGE SIDE

625mm (24 5/8")

263 mm

508 mm

(10 3/8 ")

(20 ")

 

 

 

149 mm Model 1000RHC and (5 7/8 ")

508 mm

(20 ")

INLET SIDE

Sixty Minute Remote Timer

WARRANTY

Remote Wall Mount Dehumidistat Control 24VAC only

All units conform to CSA and UL standards.

Units carry a 15 year warranty on the heat recovery cores and a 2 year replacement parts warranty.

NOTE: Hydronic reheat coil is designed to temper the ventilation air (after heat recovery) back to room temperature, and is not intended for use as a primary heating source for the space.

Additional controls MUST be added to pump system (not included / not available from Nutech) feeding the coil to ensure continuous water flow through it, and prevent freezing of the coil.

DX coil is designed to reduce humidity brought in from outside during ventilation. Coil MUST be connected to an outdoor condensing unit (not included) by certified trades person. Not intended as a primary air conditioning system for the space.