READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local regulations. To assure full compliance with local codes and regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
INSTRUCTION SHEET NO.
IS:1004ICV
B1204 Page 3 of 4
8.LAMPING (Fig. H)
1.Make sure that power is OFF when lamping or relamping. Remove LAMP RING from TRIM by pulling straight down.
2.Remove LAMP SHIELD from LAMP RING.
3.Place LAMP SHIELD on back of LAMP
WARNING: RISK OF FIRE. LAMP SHIELD MUST BE INSTALLED.
4.Attach SOCKET to bi-pin prongs on LAMP.
5.Insert LAMP RING with LAMP SHIELD, LAMP and GLASS LAMP GUARD back into TRIM.
Fig. H
INSULATING SLEEVING | MALE CONNECTORS | |
(ATTACHED TO SOCKET WIRES) | ||
| ||
FEMALE CONNECTORS |
| |
(ATTACHED TO FIXTURE WIRES) | MR16 SOCKET | |
| ||
Fig. J |
| |
LAMP | SOCKET | |
LAMP SHIELD | LAMP SPRING | |
|
GLASS LAMP GUARD | LAMP RING |
WARNING: 1. LAMP MANUFACTURERS REQUIRE THE GLASS LAMPGUARD BE IN PLACE BEFORE ENERGIZING LAMP, AND THAT GREAT CARE MUST BE TAKEN THAT LAMP IS FULLY COOLED BEFORE RELAMPING. AVOID FINGER MARKS ON INSIDE OF LAMP FOR THEY MAY CAUSE SHORT LAMP LIFE AND POSSIBLE BREAKAGE. 2. USE ONLY REFLECTOR TRIMS PROVIDED BY LIGHTOLIER INC. USE OF OTHER MANUFACTURER'S REFLECTOR TRIMS VOIDS THE UNDERWRITERS LABORATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD.
NOTE: 1. LOW VOLTAGE FIXTURES should be dimmed only with special dimmers intended specifically for that purpose. Use Lightolier Lytemode, Scenist, Crescendo VA, Neptune VA, Precision VA, Easyset VA, Sunrise VA, Radiant VA or equivalent products by others or variable autotransformers or electronic dimmers intended for use with low voltage fixtures.
2. Low voltage fixtures may produce audible sound which may be objectionable in acousti- cally critical areas.
® LIGHTOLIER a GENLYTE company.
631 Airport Road, Fall River, MA 02720