Lightolier Lighting Systems Baselyte-BSL15, Module Lengths & Mounting Distances, Type, End Set

Models: Baselyte-BSL15

1 8
Download 8 pages 20.8 Kb
Page 2
Image 2
Lighting Systems  Baselyte-BSL15

Lighting SystemsBaselyte-BSL15

Page

 

of 8

 

 

 

 

 

 

 

Performance

 

 

 

 

 

 

 

Candlepower Curve

Candlepower Summary

 

 

 







 

 

 

ZONE

 

CANDLEPOWER

 

 

 

 

 

 

 

 

 



 

 

DEG.

0

22.5

45

67.5

90

 

 

 

 

 

 

 

 

 

 



 

 

180

2038

2038

2038

2038

2038

 

 

 

 



 

175

2026

2027

2031

2036

2039

 

 

 

 



165

1952

1964

1977

1988

1994

 

 

 

 



155

1813

1832

1862

1887

1899

 

 

 

 



145

1613

1641

1697

1749

1771

 

 

 

 

135

1367

1403

1496

1611

1660

 

 

 

 

 

 

 

 

 

 

 



125

1077

1125

1307

1494

1556



 

 

 



115

751

837

1126

1263

1300

 

 

 

 



105

398

591

816

878

906



 

 

 

95

74

217

341

316

330

 

 

 



 

 

 

 

 

 

90

3

11

25

40

49



 

 

 



 

 

 

 

 

85

7

12

27

43

49

 

 

 

 

 

 

 

 

 



 



 

 

 

 

75

14

20

40

59

66

 

 

 



 







 

65

21

33

55

73

81

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55

35

49

70

86

94

 

 

 

 

 

 

Report No: 9900160

45

56

65

82

96

103

35

78

82

95

105

110

Lamps: F54T5

25

97

98

105

111

115

Lumens per Lamp: 4650

15

110

111

113

116

118

Efficiency: 80.8%

5

118

118

118

118

118

Up: 94.7% Down: 5.3%

0

119

119

119

119

119

Module Lengths & Mounting Distances

@

-ODULE ,ENGTH ,

-OUNTING $ISTANCE

@

-ODULE ,ENGTH ,-OUNTING $ISTANCE

@

-ODULE ,ENGTH ,-OUNTING $ISTANCE

Note: Shaded area indicates locations of emergency sections (emergency wiring controls all lamps or optional battery pack controls one or two lamps).

2 Light T5 HO Semi-Indirect

Coefficients of Utilization

 

 

% EFFECTIVE CEILING CAVITY REFLECTANCE

 

 

 

80

 

 

70

 

 

 

50

 

 

 

 

 

% WALL REFLECTANCE

 

 

 

 

50

30

10

50

30

10

 

50

30

10

0

78

78

78

67

67

67

 

47

47

47

1

67

64

62

58

56

53

 

41

39

38

2

59

54

50

50

47

44

 

35

33

31

3

51

46

41

44

40

36

 

31

28

26

4

45

39

35

39

34

30

 

27

24

22

5

40

34

29

34

29

26

 

24

21

18

6

35

29

25

31

26

22

 

22

18

16

7

32

26

21

27

22

19

 

19

16

14

8

28

23

19

25

20

16

 

17

14

12

9

26

20

16

22

18

14

 

16

13

10

10

23

18

14

20

16

13

 

14

11

9

Zonal Lumen Summary

 

ZONE

LUMENS

%BARE LAMP

%LUMINAIRE

0-90

397.5

4.3

5.3

90-180

7118.5

76.5

94.7

0-180

7516

80.8

100.0

Run Configuration

Run

4’

8’

12’

Joiner

End Set

Mount

Power

Length

Module

Module

Module

Mount*

 

 

 

 

 

 

 

 

 

 

 

4’ run

1

 

 

 

1

1

1

 

 

 

 

 

 

 

 

8’ run

 

1

 

 

1

1

1

 

 

 

 

 

 

 

 

12’ run

 

 

1

 

1

1

1

 

 

 

 

 

 

 

 

16’ run

 

2

 

1

1

2

1

 

 

 

 

 

 

 

 

20’ run

 

1

1

1

1

2

1

 

 

 

 

 

 

 

 

24’ run

 

 

2

1

1

2

1

 

 

 

 

 

 

 

 

28’ run

 

2

1

2

1

3

1

 

 

 

 

 

 

 

 

32’ run

 

1

2

2

1

3

1

 

 

 

 

 

 

 

 

*Note: Additional power mounts may be required for some runs with T5 HO lamping options, longer runs, and runs with wiring options that are more complex. Please consult factory for assistance.

System Components & Accessories

End Set

BSLESW = suspended standard white

Joiner

BSLJS = suspended joiner

Job Information

Type:

Lightolier a Genlyte Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.1