Lightolier DPA2G24PP332 Page 2 of, Static or Air/Return, 3 Lamp, T8 or T5, Photometry, Dp Dy Nd

Models: DPA2G24PP332

1 2
Download 2 pages 45.3 Kb
Page 2
Image 2
Page 2 of 2

 

Deepcel Plus VDT DPA2G24PP332

Page 2 of 2

2' x 4' Recessed Fluorescent, 3", 24 Cell Specular Parabolic Louver

 

Static or Air/Return, 3 Lamp, T8 or T5

Photometry

Model No. DPA2G24PP332120O3

G00065

DPA2G24PP332120

3 TL80 F32T8 / TL841. EACH RATED: 2850 LUMENS

2X4 TROFFER WITH 3X8 24 CELL SPECULAR LOUVER

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.

LER = FP - 59.8

IW - 90.4

BF - 0.89

 

 

 

 

 

 

 

 

 

 

 

Comparative yearly lighting energy cost per 1000 lumens = $4.01

 

 

 

 

 

 

coefficients of utilization — zonal cavity method

 

 

 

 

 

 

 

 

 

 

 

 

RF

 

 

 

20

 

 

 

 

20

 

 

 

 

 

 

20

 

 

 

RC

 

 

 

80

 

 

 

 

50

 

 

 

 

 

 

30

 

 

 

RW

 

70

 

50

 

30

 

50

30

 

10

 

 

50

30

10

 

 

1

 

80

 

77

 

75

 

72

71

 

69

 

 

70

68

67

 

ratio

2

 

74

 

69

 

65

 

65

63

 

60

 

 

63

61

59

 

3

 

68

 

62

 

57

 

59

55

 

52

 

 

57

54

51

 

 

 

 

 

 

 

 

 

 

cavity

4

 

63

 

56

 

51

 

53

49

 

46

 

 

52

48

45

 

5

 

58

 

50

 

45

 

48

44

 

40

 

 

47

43

40

 

room

6

 

54

 

46

 

40

 

44

39

 

36

 

 

43

38

35

 

7

 

50

 

42

 

36

 

40

35

 

32

 

 

39

35

31

 

 

8

 

47

 

38

 

33

 

37

32

 

28

 

 

36

31

28

 

 

9

 

44

 

35

 

30

 

34

29

 

26

 

 

33

29

26

 

 

10

 

41

 

32

 

27

 

31

27

 

23

 

 

31

26

23

 

visual comfort probability (VCP) average 100 fc; reflectances 80/50/20

 

 

 

 

 

 

 

room size

 

 

 

 

ceiling height

 

 

 

 

 

 

ceiling height

 

 

 

W

 

 

L

 

8.5

10.0

13.0

 

16.0

 

 

 

8.5

10.0

13.0

 

16.0

20

 

 

20

 

 

83

79

70

 

74

 

 

 

83

79

75

 

77

20

 

 

30

 

 

81

79

77

 

71

 

 

 

84

80

78

 

71

20

 

 

40

 

 

81

80

77

 

74

 

 

 

84

80

79

 

75

 

20

 

 

60

 

 

82

80

77

 

74

 

 

 

84

80

79

 

75

30

 

 

20

 

 

81

82

74

 

75

 

 

 

84

81

77

 

76

30

 

 

30

 

 

82

82

78

 

72

 

 

 

84

82

80

 

71

30

 

 

40

 

 

82

82

78

 

74

 

 

 

84

82

80

 

75

30

 

 

60

 

 

82

83

78

 

73

 

 

 

84

82

80

 

75

 

30

 

 

80

 

lengthwise

82

83

78

 

73

 

crosswise

 

84

82

80

 

75

40

 

 

40

 

82

83

79

 

74

 

 

84

82

81

 

76

40

 

 

20

 

 

81

82

76

 

77

 

 

 

84

81

79

 

78

40

 

 

30

 

luminaries

82

82

79

 

74

 

luminaries

 

84

82

81

 

73

40

 

 

60

 

82

83

79

 

75

 

 

84

82

82

 

76

40

 

 

80

 

 

82

83

79

 

75

 

 

 

84

82

82

 

76

 

40

 

 

100

 

 

82

83

80

 

75

 

 

 

84

82

82

 

76

60

 

 

30

 

 

82

83

79

 

76

 

 

 

84

82

81

 

73

60

 

 

40

 

 

82

83

79

 

76

 

 

 

84

82

82

 

76

60

 

 

60

 

 

82

83

79

 

76

 

 

 

84

82

82

 

76

 

 

 

 

 

 

 

60

 

 

80

 

 

82

83

80

 

76

 

 

 

84

82

82

 

76

 

60

 

 

100

 

 

82

83

80

 

76

 

 

 

84

82

82

 

76

100

 

 

40

 

 

82

83

79

 

76

 

 

 

84

82

82

 

76

100

 

 

60

 

 

82

83

80

 

76

 

 

 

84

82

82

 

76

100

 

 

80

 

 

82

83

80

 

77

 

 

 

84

82

81

 

76

 

100

 

 

100

 

 

82

83

80

 

77

 

 

 

85

82

81

 

76

Ordering Information

Explanation of Catalog Number. Example: DPA2G24PP332120O3CP

2

 

 

 

 

24

 

 

 

 

 

 

 

 

P

 

3

 

 

 

 

 

Deepcel Plus

Parabolic:

Pre-anodized

aluminum

louver

 

 

 

 

 

Number of

Louver Finish:

Body Style:

 

Fixture

Ceiling Type:

A=Air Supply

 

Width

G= Grid

Cells:

L = Low

S=Static

 

 

(lay-in T bar)

24=3 rows

iridescence

 

 

 

 

 

 

F= Flanged (over

of 8

Semi-specular

 

 

 

 

lap) Z spline and

 

(standard)

 

 

 

 

plaster frame

 

P =Low

Dual "V"

Lamp

 

 

 

 

Options:

Reflectors

Quantity

Voltage:

Add appropriate

 

 

suffix to catalog no.,

 

 

120, 277 or

ie: (CP)

 

 

UNV=120-277

 

 

 

 

 

 

 

DP

DY

ND

 

T= Slot grid or

iridescence

Standard Deepcel

two-directional

Specular

concealed T

W =White Baked

 

(see options)

Enamel

For NYC Code – I.B.E.W. Manufactured

For NYC Code – Local 3 Manufactured 5½" Deep Body

Lamp Type/

Fixture Length:

32=32W T8

28=28W T5

54=54W T5 (Nominal 48")

 

Ballast Type:

<10THD

 

<20THD

1

& 2 Lamp Elec. T8

SO *

HI *

1-3 Lamp Elec. T8

O3 *

H3 *

1

& 2 Lamp 28W Elec. T5

PI

1

& 2 Lamp 28W Elec. T5

PG ††

1-3 Lamp 54W Elec. T5

P5 ††

LOL T8 Dimming

PS

Other dimming options. Consult factory.

*Instant Start Standard †Instant Start (120, 277 or UNV) ††Program Rapid Start (UNV only)

NOTE:I

For T8 UNV, you must use H , H3 Ballast Code.

Options/Accessories

Plaster Frame: Catalog Number: PF24.

Continuous Row Installation: For F type fixtures, half width flanges are required between

fixtures. Order Catalog Number: 2FC TRIM CSP (each joint).

Radio Interference Filter: To order one RIF per fixture; SUFFIX: R. To order one RIF per ballast;

SUFFIX: B.

Electrical Wiring Options: Consult factory.

Air Closure Strip: SUFFIX: ACS4 (factory installed).

Drywall Kit: Order Catalog Number: FK92X4. (Request Folio OA30-10 Rev. A).

Chicago Plenum: SUFFIX: CP.

Specifications (continued)

Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. Louver–low iridescence semi- specular anodized vertical grain aliminum reflector sheet is standard.

Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is with- in 3" of ballast, use wire suitable for at least 90°.

Labels: I.B.E.W. UL and ULc Listed.

Specifications

Performance: In an installation of 3 lamp 32W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .77. To prevent glare the VCP shall be not less than 82 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 850, 57 and 56 candelas per square meter respectively in the O°, 45°, and 90° horizontal planes.

Air Handling (DPA only) side air passages for air supply or air return. Supply air is discharged vertically. Optional side closure strips. Air return is also provided through the lamp compartment through fixture body ends.

Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing is ribbed for rigidity with side rails hemmed over and housing ends turned-in for safe handling. Louver is pre-anodized aluminum (Coilzak® or equal.

 

Job Information

Type:

 

 

 

Lightolier a Genlyte companywww.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2007 a Genlyte company

Section 2/Folio G51-48 Rev. A

Page 2
Image 2
Lightolier DPA2G24PP332 Page 2 of, Static or Air/Return, 3 Lamp, T8 or T5, Photometry, Ordering Information, Dp Dy Nd