| Deepcel Plus VDT DPA2G24PP332 |
Page 2 of 2 | 2' x 4' Recessed Fluorescent, 3", 24 Cell Specular Parabolic Louver |
| Static or Air/Return, 3 Lamp, T8 or T5 |
Photometry | Model No. DPA2G24PP332120O3 |
G00065
DPA2G24PP332120
3 TL80 F32T8 / TL841. EACH RATED: 2850 LUMENS
2X4 TROFFER WITH 3X8 24 CELL SPECULAR LOUVER
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.
LER = FP - 59.8 | IW - 90.4 | BF - 0.89 |
|
|
|
|
|
|
|
|
|
|
| ||||||
Comparative yearly lighting energy cost per 1000 lumens = $4.01 |
|
|
|
|
| ||||||||||||||
| coefficients of utilization — zonal cavity method |
|
|
|
|
|
|
|
|
|
| ||||||||
|
| RF |
|
|
| 20 |
|
|
|
| 20 |
|
|
|
|
|
| 20 |
|
|
| RC |
|
|
| 80 |
|
|
|
| 50 |
|
|
|
|
|
| 30 |
|
|
| RW |
| 70 |
| 50 |
| 30 |
| 50 | 30 |
| 10 |
|
| 50 | 30 | 10 | |
|
| 1 |
| 80 |
| 77 |
| 75 |
| 72 | 71 |
| 69 |
|
| 70 | 68 | 67 | |
| ratio | 2 |
| 74 |
| 69 |
| 65 |
| 65 | 63 |
| 60 |
|
| 63 | 61 | 59 | |
| 3 |
| 68 |
| 62 |
| 57 |
| 59 | 55 |
| 52 |
|
| 57 | 54 | 51 | ||
|
|
|
|
|
|
|
|
| |||||||||||
| cavity | 4 |
| 63 |
| 56 |
| 51 |
| 53 | 49 |
| 46 |
|
| 52 | 48 | 45 | |
| 5 |
| 58 |
| 50 |
| 45 |
| 48 | 44 |
| 40 |
|
| 47 | 43 | 40 | ||
| room | 6 |
| 54 |
| 46 |
| 40 |
| 44 | 39 |
| 36 |
|
| 43 | 38 | 35 | |
| 7 |
| 50 |
| 42 |
| 36 |
| 40 | 35 |
| 32 |
|
| 39 | 35 | 31 | ||
|
| 8 |
| 47 |
| 38 |
| 33 |
| 37 | 32 |
| 28 |
|
| 36 | 31 | 28 | |
|
| 9 |
| 44 |
| 35 |
| 30 |
| 34 | 29 |
| 26 |
|
| 33 | 29 | 26 | |
|
| 10 |
| 41 |
| 32 |
| 27 |
| 31 | 27 |
| 23 |
|
| 31 | 26 | 23 | |
| visual comfort probability (VCP) average 100 fc; reflectances 80/50/20 |
|
|
|
|
| |||||||||||||
|
| room size |
|
|
|
| ceiling height |
|
|
|
|
|
| ceiling height |
|
| |||
| W |
|
| L |
| 8.5 | 10.0 | 13.0 |
| 16.0 |
|
|
| 8.5 | 10.0 | 13.0 |
| 16.0 | |
20 |
|
| 20 |
|
| 83 | 79 | 70 |
| 74 |
|
|
| 83 | 79 | 75 |
| 77 | |
20 |
|
| 30 |
|
| 81 | 79 | 77 |
| 71 |
|
|
| 84 | 80 | 78 |
| 71 | |
20 |
|
| 40 |
|
| 81 | 80 | 77 |
| 74 |
|
|
| 84 | 80 | 79 |
| 75 | |
| 20 |
|
| 60 |
|
| 82 | 80 | 77 |
| 74 |
|
|
| 84 | 80 | 79 |
| 75 |
30 |
|
| 20 |
|
| 81 | 82 | 74 |
| 75 |
|
|
| 84 | 81 | 77 |
| 76 | |
30 |
|
| 30 |
|
| 82 | 82 | 78 |
| 72 |
|
|
| 84 | 82 | 80 |
| 71 | |
30 |
|
| 40 |
|
| 82 | 82 | 78 |
| 74 |
|
|
| 84 | 82 | 80 |
| 75 | |
30 |
|
| 60 |
|
| 82 | 83 | 78 |
| 73 |
|
|
| 84 | 82 | 80 |
| 75 | |
| 30 |
|
| 80 |
| lengthwise | 82 | 83 | 78 |
| 73 |
| crosswise |
| 84 | 82 | 80 |
| 75 |
40 |
|
| 40 |
| 82 | 83 | 79 |
| 74 |
|
| 84 | 82 | 81 |
| 76 | |||
40 |
|
| 20 |
|
| 81 | 82 | 76 |
| 77 |
|
|
| 84 | 81 | 79 |
| 78 | |
40 |
|
| 30 |
| luminaries | 82 | 82 | 79 |
| 74 |
| luminaries |
| 84 | 82 | 81 |
| 73 | |
40 |
|
| 60 |
| 82 | 83 | 79 |
| 75 |
|
| 84 | 82 | 82 |
| 76 | |||
40 |
|
| 80 |
|
| 82 | 83 | 79 |
| 75 |
|
|
| 84 | 82 | 82 |
| 76 | |
| 40 |
|
| 100 |
|
| 82 | 83 | 80 |
| 75 |
|
|
| 84 | 82 | 82 |
| 76 |
60 |
|
| 30 |
|
| 82 | 83 | 79 |
| 76 |
|
|
| 84 | 82 | 81 |
| 73 | |
60 |
|
| 40 |
|
| 82 | 83 | 79 |
| 76 |
|
|
| 84 | 82 | 82 |
| 76 | |
60 |
|
| 60 |
|
| 82 | 83 | 79 |
| 76 |
|
|
| 84 | 82 | 82 |
| 76 | |
|
|
|
|
|
|
| |||||||||||||
60 |
|
| 80 |
|
| 82 | 83 | 80 |
| 76 |
|
|
| 84 | 82 | 82 |
| 76 | |
| 60 |
|
| 100 |
|
| 82 | 83 | 80 |
| 76 |
|
|
| 84 | 82 | 82 |
| 76 |
100 |
|
| 40 |
|
| 82 | 83 | 79 |
| 76 |
|
|
| 84 | 82 | 82 |
| 76 | |
100 |
|
| 60 |
|
| 82 | 83 | 80 |
| 76 |
|
|
| 84 | 82 | 82 |
| 76 | |
100 |
|
| 80 |
|
| 82 | 83 | 80 |
| 77 |
|
|
| 84 | 82 | 81 |
| 76 | |
| 100 |
|
| 100 |
|
| 82 | 83 | 80 |
| 77 |
|
|
| 85 | 82 | 81 |
| 76 |
Ordering Information
Explanation of Catalog Number. Example: DPA2G24PP332120O3CP
2 |
|
|
|
| 24 | ||
|
|
|
|
|
|
|
|
P |
| 3 | ||
|
|
|
|
|
Deepcel Plus
Parabolic:
aluminum
louver
|
|
|
|
| Number of | Louver Finish: |
Body Style: |
| Fixture | Ceiling Type: | |||
A=Air Supply |
| Width | G= Grid | Cells: | L = Low | |
S=Static |
|
| 24=3 rows | iridescence | ||
|
| |||||
|
|
|
| F= Flanged (over | of 8 | |
|
|
|
| lap) Z spline and |
| (standard) |
|
|
|
| plaster frame |
| P =Low |
Dual "V" | Lamp |
|
|
|
| Options: | |||
Reflectors | Quantity | Voltage: | Add appropriate | |
|
| suffix to catalog no., | ||
|
| 120, 277 or | ie: (CP) | |
|
|
|
| |
|
|
|
|
|
DP
DY
ND
| T= Slot grid or | iridescence |
Standard Deepcel | Specular | |
concealed T | W =White Baked | |
| (see options) | Enamel |
For NYC Code – I.B.E.W. Manufactured
For NYC Code – Local 3 Manufactured 5½" Deep Body
Lamp Type/
Fixture Length:
32=32W T8
28=28W T5
54=54W T5 (Nominal 48")
| Ballast Type: | <10THD | |
| <20THD | ||
1 | & 2 Lamp Elec. T8 | SO * | HI * |
O3 * | H3 * | ||
1 | & 2 Lamp 28W Elec. T5 | – | PI † |
1 | & 2 Lamp 28W Elec. T5 | – | PG †† |
– | P5 †† | ||
LOL T8 Dimming | PS | – |
Other dimming options. Consult factory.
*Instant Start Standard †Instant Start (120, 277 or UNV) ††Program Rapid Start (UNV only)
NOTE:I
For T8 UNV, you must use H , H3 Ballast Code.
Options/Accessories
Plaster Frame: Catalog Number: PF24.
Continuous Row Installation: For F type fixtures, half width flanges are required between
fixtures. Order Catalog Number: 2FC TRIM CSP (each joint).
Radio Interference Filter: To order one RIF per fixture; SUFFIX: R. To order one RIF per ballast;
SUFFIX: B.
Electrical Wiring Options: Consult factory.
Air Closure Strip: SUFFIX: ACS4 (factory installed).
Drywall Kit: Order Catalog Number: FK92X4. (Request Folio
Chicago Plenum: SUFFIX: CP.
Specifications (continued)
Finish: Chassis
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is with- in 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W. UL and ULc Listed.
Specifications
Performance: In an installation of 3 lamp 32W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .77. To prevent glare the VCP shall be not less than 82 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 850, 57 and 56 candelas per square meter respectively in the O°, 45°, and 90° horizontal planes.
Air Handling (DPA only) side air passages for air supply or air return. Supply air is discharged vertically. Optional side closure strips. Air return is also provided through the lamp compartment through fixture body ends.
Materials: Chassis parts are
| Job Information | Type: |
|
|
| ||
Lightolier a Genlyte company | www.lightolier.com |
Technical Information: (978)
631 Airport Road, Fall River, MA 02720 • (508)
© 2007 a Genlyte company | Section 2/Folio |