Harman Stove Company HB 38 DV manual Specifications, Top Vent, Rear Vent

Models: HB 38 DV

1 46
Download 46 pages 46.8 Kb
Page 8
Image 8
SPECIFICATIONS

SPECIFICATIONS

Top Standoffs

Vent Collar

Accordion Heat

Exchanger

Top VentRear VentManual backgroundManual backgroundManual background Glass Door

Brick

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background Burner Module

Electrical Box

On-Off- Thermostat

Switch

Blower Speed Switch

 

 

 

Ignitor

 

Battery

 

On-Off-Pilot Knob

Blower

Pack

 

Rear Burner

Hi-Low Knob

 

 

 

Switch

 

 

 

 

Top Vent

Rear Vent

RATINGS

NATURAL

PROPANE

NATURAL

PROPANE

Input Rating (Btu/hr)(0-4500 ft.)(0-1375 m)

43500

43500

41500

41400

Min. Input Rating (Btu/hr)(0-4500 ft.)(0-1375 m)

23300

23800

22800

23400

Orifices (DMS)(front/rear)(0-4500 ft.)(0-1375 m)

31/51

52/59

32/51

52/60

Manifold Pressure (in w.c./kPa)

3.5/0.87

10.0/2.49

3.5/.087

10.0/2.49

Min. Manifold Pressure (in w.c./kPa)

1.7/0.42

6.3/1.6

1.7/0.42

6.3/1.55

Min. Inlet Pressure (in w.c./kPa)

5.0/1.25

11.0/2.74

5.0/1.25

11.0/2.74

Max. Output (Btu/hr)(0-4500 ft.)(0-1375 m) (Blower Off)

31500

32000

31000

31000

Max. Efficiency (Blower On) top vent 84.5%, rear vent 75%

 

 

 

 