Harman Stove Company HB 38 DV VENTING Damper Settings, Range Of Approved Damper Settings, Propane

Models: HB 38 DV

1 46
Download 46 pages 46.8 Kb
Page 24
Image 24
VENTING

Only For Qualified Installers

VENTING

Damper Settings

Top Vent Only

Vent damper in the number “4” position

Maximum Draft

Minimum Draft

A vent damper is provided on top vent models to allow fine tuning of the draft. Too little draft will cause flames to be too long with black tips and too much draft will cause flames to be short and blue.

To adjust the damper, burn the unit on high with both burners for 10 minutes or more. Adjust the vent damper to a position in the ranges listed below that produces the most desirable flame pattern. Note: 1 is less draft and 4 is maximum draft.

Range Of Approved Damper Settings

Range Of Approved Damper Settings

For 8” X 5” Vent

 

For 6 5/8” X 4” Vent

 

 

Natural Gas

Propane

 

Natural Gas

Propane

6

feet

2 1/2

1 to 4

12 feet

1 to 4

1 to 4

12

feet

2 1/2 to 4

1 to 4

24 feet

1 to 4

1 to 4

24 feet

1 to 2

1 to 4

36 feet

1 to 4

1 to 4

36 feet

1

2 to 4

 

 

 

24

Page 24
Image 24
Harman Stove Company HB 38 DV VENTING Damper Settings, Range Of Approved Damper Settings, For 8” X 5” Vent, Propane, feet