Only For Qualified Installers | INSTALLATION (Options) |
Installing the Floor Register
Breakoff Tabs
Tilt Blower Box
Mounting Screws
The blower box mounting bracket is designed to allow mounting into an existing floor. However, it is easier to in- stall all components at the time of house
construction. The mounting bracket as- sumes that floor joists are on 16” cen-
ters. The mounting bracket has
1.Cut a 71/2 x 137/8 hole in the floor at the proper location. The hole must be perpendicular to the floor joists.
2.Place the mounting bracket in the hole as shown. The tapered end of the bracket must be opposite to the side where the air will enter the blower box.
3.Place the blower box with blower assembly removed, down into the bracket, angling it as shown. Slide the blower box down into the bracket as far as needed to tilt it level. Then slide the box in position and attach the duct work (not shown). Install the box mounting screws.
4.Insert the electrical wires for the blower into the box through one of the two holes provided.
5.Using wire nuts, connect the wires to the motor and speed control as shown on the wiring diagram.