INSTALLATION

Only For Qualified Installers

Drywall Bracket

Nails Victorian Face

INSTALLATION

Installing Fireplace To use

Victorian Face

Nails

When installing the fireplace to use the Victo- rian Face the unit must be positioned back 1/2 inch farther than with an arch face. A special drywall bracket must be used to allow the drywall to extend down far enough so the face will cover the drywall. 1. Install drywall bracket on top of the stand-offs

with two screws.

2. Place the fireplace into the framed opening so the two ends of the drywall bracket rest against the framing. This will position the face of the fireplace 1/2 inch back from the face of the framing.

3. Nail or screw the drywall bracket fast to the framing.

4. Install and finish drywall as desired. Drywall shall not extend below the drywall bracket on the top and not closer to the fireplace cabinet

Drywall Bracket

Drywall

than the vertical wood framing on the sides.

Victorion Face

Standoff

Drywall in Place

17