Only For Qualified Installers | INSTALLATION |
|
|
|
|
Remove Orifices with a 1/2” wrench | 9 | Orifice Chart |
|
| |
or deep well socket. The larger | Vent | Natural | Propane | ||
orifice always goes to the front. | |||||
|
| Front | Rear | Front | Rear |
| Top | 31 | 51 | 52 | 59 |
| Rear | 32 | 51 | 52 | 60 |
10Replace Orifices with the proper size shown in the Orifice Chart.
11
Remove two screws and place Control Panel to the left.
Note: The higher the orifice number the smaller hole in the tip. For example, a number 52 oifice has a larger hole than a number 60 orifice.
12Read instructions packed with LP
13
Remove three screws to change knob assembly. Install LP knob assembly in place of the NG assembly. Be sure screws are tight.
14
Place conversion sticker (provided in Kit) on bottom of valve. This is to permanently mark the valve that it has been converted to LP. This label is important in the event that the valve is ever removed and mixed in with other valves.
Mark the proper box on the control panel with a permanent
15marker. Note: If no conversion is made, the box for the proper fuel must still be marked.
26