Listed Direct Vent Gas Fireplace Heater
Radiateur Ventile
Model: Serenity III HB 38DV
WHI #
TOP VENT REAR VENT
Homologue Pour Le Canada
Do not remove or cover this label.
Not for use with solid fuel. Not for use with air filters Ne doit pas etre utilise avec un combustible solide.
| TOP VENT |
| REAR VENT |
|
RATINGS | NATURAL | PROPANE | NATURAL | PROPANE |
Input Rating | 43500 | 43500 | 41500 | 41400 |
Min. Input Rating | 23300 | 23800 | 22800 | 23400 |
Orifices | 31/51 | 52/59 | 32/51 | 52/60 |
Manifold Pressure (in w.c./kPa) | 3.5/0.87 | 10.0/2.49 | 3.5/.087 | 10.0/2.49 |
Min. Manifold Pressure (in w.c./kPa) | 1.7/0.42 | 6.3/1.6 | 1.7/0.42 | 6.3/1.55 |
Min. Inlet Pressure (in w.c./kPa) | 5.0/1.25 | 11.0/2.74 | 5.0/1.25 | 11.0/2.74 |
Max. Output | 31500 | 32000 | 31000 | 31000 |
Max. Efficiency (Blower On) top vent 84.5%, rear vent 75% |
|
|
|
|
Also for use in mobile (manufactured) homes after home is sited. Tested to ANSI
Pour utilisation, avec le gaz naturel et le propane. Une trousse
de conversion fourniepar le fabricant doit etre utilisee pour passer d’un combustible a l’autre.
39
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUC-
TION |
|
Unit to floor | 0 in. |
Face to side wall | 7 in. |
Unit to top | 0 in. |
Unit to side | 0 in. |
Unit to rear | 0 in. |
Top of Glass to 7” Mantel | 26in. |
Electrical Rating: 120 Volts, 60 Hs, >2.75 AMP
One or two optional register kits (Part No.
A LABEL ON THE BURNER SYSTEM MODULE STATES THE FUEL FOR WHICH THE HEATER IS EQUIPPED.
Manufactured by Harman Stove Company 352 Mountain House Road, Halifax, PA 17032