![MAINTENANCE](/images/new-backgrounds/55230/5523069x1.webp)
MAINTENANCE
A qualified service person recommended by your Harman dealer should conduct an annual in- spection and maintenance of your fireplace, its vent- ing, and the installation to keep it running safely and efficiently. The following procedures should be per- formed only by a qualified service person. The gas supply should be turned off whenever a maintenance procedure is performed.
If the glass front, side doors, or front access door are removed for servicing, they must be re- placed prior to operating the fireplace.
Latches
Slot
WARNING: DO NOT OPERATE THIS APPLIANCE WITH TH GLASS FRONT REMOVED, CRACKED OR BROKEN. REPLACEMENT OF GLASS SHOULD BE DONE BY A LICENSED OR QUALIFIED SERVICE PERSON. NEVER USE SUBSTITUTE MATERIALS.
DO NOT STRIKE OR SLAM GLASS
Removing the Glass Front
If the fireplace has an arch face, remove the face as described on page 11.
If the fireplace has a Victorian face, open the bottom and top doors.
Lift the latches shown above and tilt the glass out at the top and lift it out of the groove at the bot- tom. Handle the glass with care.
Replacing the Gasket
The Serenity uses part no.
1.Lay glass front face down.
2.Bend four tab up far enough to remove the glass.
3.Remove old gasket.
4.Install new gasket around glass.
5.Place glass back in frame.
6.Bend tabs to secure glass. Not too tight.
7.Reinstall glass door by placing the flange on the bottom of the door into the groove on the bottom of the fireplace opening. Next lift the latches and push the door against the unit. Pull the spring loaded latches front until the tabs drops into the slots on the door frame
Cleaning the Glass
The glass may be cleaned with ordinary house- hold glass cleaner and a soft cloth or paper towel.
WARNING: Never clean the glass when it is hot. Do not use abrasive cleaners on the glass. Inspecting the Venting
An inspection of both the inner and outer pipes of the venting system should be made during the annual service appointment. They must have no blockage and be in good repair. The vent manufacturer's instructions may provide specific suggestions or details on vent inspection. Any sec- tions that are taken apart for the inspection must be reassembled and sealed as required.
Cleaning the Log Set and Firebox
During the annual inspection and maintenance appointment, the service person should clean dust, lint, and any light accumulation from the logs and the firebox area. An
35