![VENTING](/images/new-backgrounds/55230/5523041x1.webp)
Only For Qualified Installers
This appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance.
VENTING
Venting with 8” x 5” Pipe
Maximum of four 450 elbows allowed. Subtract three feet of total horizontal pipe length for each of the 3rd and 4th 450 elbows used.
Maximum of two 900 elbows allowed. Subtract five feet of total horizontal pipe length for second elbow.
A combination of one 900 elbow and two 450 elbows is allowed.
Subtract three feet of total horizontal pipe length for each 450 elbow used.
Vent termination must remain within the shaded area regardless of configuration.
Rear Vent Model
Maximum horizontal rear vent run is 24 inches . Vertical venting of the rear vent model is not
approved. Never used 6 5/8” x 4” pipe for rear
vent.
21