Air Flow

MAINTENANCE

Air Out

Air In

The flow of combustion and ventilation air must not be obstructed

Oil Holes

Air Flow

It is essential the air flows freely into the bot- tom grill and out of the top grill. Do not place ob- jects in front of the grills.

Check blower annually for buildup caused by dust and pet hair.

Cleaning the Burners

To clean the burners the face, glass front, and logs must be removed. Remove the front burner as- sembly and rear burner as described on page 22. Re- move the front burner from the assembly by loosen- ing the clamping plate on the bottom.

With both burners removed, inspect all the hole to make sure they are unobstructed. Use a small drill or wire to clean any obstructed holes. Remove any rust or other buildup that may have accumulated.

Replace burners in reverse order.

Lubrication

The Serenity Fireplace does not require lubri- cation other than the blower. One or two drops of light oil may be put in the two oil holes on the blower motor. This is not critical and should only be done every year or two. Too much oil is worse than no oil.