Harman Stove Company HB 38 DV Is Pilot lit, Replace valve, marked TP on valve, wiring connectors

Models: HB 38 DV

1 46
Download 46 pages 46.8 Kb
Page 44
Image 44
Is Pilot lit

Only For Qualified Installers TROUBLE SHOOTING

Main Burner will not light (with valve in "on" position)

Is Pilot lit

no

Light pilot

Yes

Check Thermopile voltage at terminals

marked TP on valve.

Should be approximately too low Replace Thermopile 200 mv with switch "on"

and approximately 400 mv with switch "off".

OK

Check switch, wires, and

bad

Correct problem

wiring connectors.

 

 

OK

Replace valve

44

Page 44
Image 44
Harman Stove Company HB 38 DV Is Pilot lit, Replace valve, marked TP on valve, Check switch, wires, and, wiring connectors