FRU and Error Code Table

Use the information in the following table to identify the failing FRU (field replaceable unit). Part numbers for FRUs are listed in “Service Parts” on page 4-22.

Note:

Without

manual

intervention, the

diagnostics

take

two

or three

 

minutes

to

run.

If

the

diagnostic tests run for more than one

 

minute

for

any

routine,

suspect

a faulty

base

card.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error

Code

Range

 

 

 

 

Replace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00–85

 

 

 

 

 

Base

card

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

87–FF

 

 

 

 

 

Base

card

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

86

 

 

 

 

 

 

Interface

cable

 

 

 

 

 

 

 

 

 

 

 

 

LED (always On, always Off,

orBase card

 

 

 

 

 

 

blinking)ñ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ñ

When

the

system

is

powered on,

the

LED

should come on

for

a few

seconds

 

and

then

go

off

and remain

off.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4-12X.25 Co-Processor PCI GTO

Page 40
Image 40
IBM X.25 manual FRU and Error Code Table