Lightolier specifications Calculite Incandescent Open Downlight G7057

Models: G7057

1 2
Download 2 pages 24.61 Kb
Page 1
Image 1
Calculite® Incandescent Open Downlight G7057

Calculite® Incandescent Open Downlight G7057

Page 1 of 2

 

 

4 1/2" Aperture A19 Lamp Horizontal

2

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12"

3-3/8"

12-1/2" 4 1/2" Aperture A19 Lamp Horizontal

Top View

5-5/8" 3"

1" min.-

2-1/8" max.3 4 (Ceiling Runner)

4-1/8" Dia. Manual background

5-5/8"5-3/4"

FlushOverlap

5

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1" max.

 

 

7

 

Ceiling Thickness

Flush Trim

Molded

Overlap Self-Flange

(Molded trim ring removed)

Trim Ring

Matte White or Polished

Ceiling Cutout: 5 1/16" Dia.

 

 

Reflector Trims

Frame-In Kit

Lamp

G7057CLW

Specular Clear finish with white flange

G410

A19, 100W max.

G7057CLP

Specular Clear finish with polished flange

 

 

Remodeler

Lamp

G7057CL

Specular Clear finish with molded trim ring (flangeless)

G7057

 

Add suffix for other finishes (see options)

G410RM

Same as G410

 

 

 

 

 

 

 

 

Features

1.Socket Cup: Heat-dissipating die-formed aluminum contains medium base porcelain socket with nickel plated screw shell wired with No. 18 SF1 leads to J-Box. Installs on reflector with positive position locking springs to assure proper optical alignment of lamp to reflector—attached without tools.

2.Mounting Brackets: Adjust vertically from inside of fixture. Durable 16 ga. steel construction. Use with standard 3/4" or 1 1/2" lathing channels (by oth- ers), or Lightolier accessory mounting bars.

3.Retaining Springs: Precision-tooled springs secure reflector to mounting frame for quick tool-less installation.

4.Reflector: 16 ga. Specular Alzak® aluminum, 50° visual cut-off to lamp and lamp image. Available with white or polished flange, or with removable white molded trim ring (field paintable).

5.Junction Box: 14 ga. steel, 4" x 4" x 2" box allows inspection from below.

6.Thermal Protector: Meets NEC and UL requirements. Insulation must be kept 3" away from fixture sides and wiring compartments and must not be placed above fixture in a manner which will entrap heat.

7.Mounting Frame: Die-cast aluminum suitable for dry or plaster ceilings. Provides flangeless trim in plaster ceiling.

Options & Accessories

18" Mounting Bars

1950

(set of 2)

27" Mounting Bars

1951

(set of 2)

T-Bar Anchor Clips

1956

(set of 4, for 1950 & 1951 bars)

Existing Ceiling Clips

7998

(set of 2)

Sloped Ceiling Adapters

See SCA specification sheet

Step Down Transformer

7997

(see separate specification sheet)

Chicago Air Plenum

LC (add suffix to Frame-in Kit, requires access

 

from above ceiling)

Electrical

UL Listed for maximum of 8 No. 12, 75°C through branch circuit supply conduc- tors, or 60°C conductors for end of run.

Labels

UL Listed for damp locations, I.B.E.W.

Alzak® is a registered trademark of ALCOA.

Other Reflector Finish Options

Comfort Clear Diffuse

CCD

Specular Gold

GD

White

WH

Flange Options

White

W

Polished Flange

P

Flangeless

Leave Blank (molded trim ring)

Job Information

Type:

 

 

Job Name:

Cat. No.:

Lamp(s):

Notes:

Lightolier a Genlyte Thomas Companywww.lightolier.com 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) • A0902