Lightolier H9S1GLR254 Page 2 of, Ordering Information, Options/Accessories, Specifications, Type

Models: H9S1GLR154 H9S1GLR254

1 2
Download 2 pages 51.5 Kb
Page 2
Image 2
Page 2 of 2

 

HP90 Recessed Fluorescent H9S1GLR254 or 154

Page 2 of 2

Direct/Indirect – 1' x 4' with Acrylic Linear Prismatic Lens

 

Static, 1 or 2 Lamp T5

Model No. H9S1GLR154UNVPG

LER = FP - 56.9 IW - 61.0 BF - 1.0 Comparative yearly lighting energy cost per

1000 lumens = $4.21

Report Number: G2006142

Catalog Number: H9S1GLR154UNVPG

Lamps: F54 T5 HO

Luminaire: HP90 1' x 4' with linear prismatic lens.

Ballast: Advance ICN-2S54-90C

Report is based on 4400 Lumens per lamp. Efficiency: 79.1%

CIE Type-Direct-Indirect

 

Plane:

0-Deg

90-Deg

Spacing Criteria:

1.3

1.3

Shielding Angles:

90

90

Plane:

0-Deg

90-Deg

Luminous Length:

46.760

11.760

COEFFICIENTS OF UTILIZATION – ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

87

83

80

78

76

73

75

73

71

02

79

73

68

69

65

61

66

63

60

03

72

64

58

61

56

52

59

54

51

04

66

57

51

54

49

44

52

48

44

05

61

51

44

49

43

39

47

42

38

06

57

46

39

44

38

34

43

38

34

07

52

42

35

40

34

30

39

34

30

08

49

38

32

37

31

27

36

31

27

09

46

35

29

34

28

34

33

28

24

10

43

33

26

31

26

22

31

26

22

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE IN DEG. 0-DEG. 45-DEG. 90-DEG.

45 3483. 3195. 3316.

55 3044. 2929. 3040.

65 2383. 2408. 2500.

75 1705. 1908. 1897.

85 918. 981. 886.

CANDELA DISTRIBUTION0

 

 

 

0.0

45.0

90.0

FLUX

0

1303

1303

1303

 

5

1288

1304

1319

124

15

1249

1286

1305

363

25

1175

1202

1207

552

35

1059

1036

1023

649

45

880

819

850

647

55

633

609

632

548

65

365

369

383

373

75

160

179

178

189

85

29

31

28

37

90

2

2

2

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

1039

23.6

29.8

00-040

1688

38.4

48.5

00-060

2883

65.5

82.8

00-090

3481

79.1

100.0

90-180

0000

0.0

000.0

00-180

3481

79.1

100.0

Model No. H9S1GLR254UNVPG

LER = FP - 62.9 IW - 109.0 BF - 1.0 Comparative yearly lighting energy cost per

1000 lumens = $3.82

Report Number: G2006165

Catalog Number: H9S1GLR254UNVPG

Lamps: F28 T5 HO

Luminaire: HP90 1' x 4' with linear prismatic lens.

Ballast: B254I UNV-E

Report is based on 4400 Lumens per lamp. Efficiency: 77.9%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.3

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

46.800

 

10.800

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

85

82

78

77

74

72

74

72

70

02

78

72

66

67

63

60

65

62

59

03

71

63

57

60

55

51

57

53

50

04

65

56

49

53

48

43

51

47

43

05

60

50

43

48

42

38

46

41

37

06

55

45

38

43

37

33

42

37

33

07

51

41

34

39

34

29

38

33

29

08

48

38

31

36

30

26

35

30

26

09

45

34

28

33

28

24

32

27

24

10

42

32

26

31

25

21

30

25

21

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

6941.

7205.

7114.

55

6307.

6430.

6349.

65

5194.

5411.

5556.

75

3838.

4442.

4465.

85

2216.

2743.

2603.

CANDELA DISTRIBUTION0

 

 

 

0.0

45.0

90.0

FLUX

0

2472

2472

2472

 

5

2443

2467

2491

236

15

2358

2452

2533

693

25

2189

2362

2406

1073

35

1936

2082

2071

1282

45

1601

1662

1641

1272

55

1180

1203

1188

1071

65

716

746

766

748

75

324

375

377

394

85

63

78

74

90

90

15

15

15

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

2002

22.7

29.2

00-040

3283

37.3

47.9

00-060

5626

63.9

82.0

00-090

6858

77.9

100.0

90-180

0000

0.0

000.0

00-180

6858

77.9

100.0

Ordering Information

Explanation of Catalog Number. Example: H9S1GLR154UNVPGGLR

 

 

 

 

 

S

 

1

 

 

 

 

 

 

 

 

 

 

 

HP90

 

Body Style:

 

Fixture

Direct/Indirect

 

S = Static

 

Width

 

Recessed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H9

Standard HP90

 

 

 

 

 

 

 

 

HY

 

For NYC Code – I.B.E.W. Manufactured

 

 

 

 

HN

For NYC Code – Local 3 Manufactured

G

 

L

Ceiling

 

Type:

 

 

 

Acrylic Lens

Fits both

 

 

Standard Grid

 

 

and

 

 

Slot Grid

 

 

R

Reflector:

Specular

Aluminum

 

 

 

54

 

 

 

 

Lamp

Lamp:

Quantity

(By Others)

1=1 Lamp

54=T5 54W

2=2 Lamp

(Nominal 48")

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage:

 

 

 

Options:

120, 277 or

 

 

Add appropriate

UNV=120-277

 

 

suffix to catalog

 

 

 

 

 

 

 

no., ie: (GLR)

 

 

 

Ballast Type:

 

 

 

 

 

 

 

 

 

<20THD <10THD

1 Lamp Elec. T5 HO

 

 

PG ††

 

(54 Watt)

 

 

 

PG ††

2 Lamp Elec. T5 HO

 

 

 

(54 Watt)

 

 

 

 

 

 

††Program Rapid Start (UNV only)

Options/Accessories

Fusing: Internal fast blow fusing: SUFFIX: GLR.

Internal slow blow fusing: SUFFIX: GMF.

Drywall Kit: Order Catalog Number: FK91X4.

Electrical Wiring Options: Consult factory.

Optional motion or light sensor: Request Folio OA20-10.

Specifications

Performance: In an installation of 2 lamp 54W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .83. To reduce glare the average brightness at 65° shall not exceed 2500 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 70.2%.

Materials: Chassis parts are die-formed code gauge steel.

Lamp Shield: Linear prismatic translucent DR acrylic lens.

Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat white acrylic enamel. Reflector – low iridescence specular aluminum 95% reflectance. Phosphate undercoating.

Specifications (continued)

Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed.

This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org

Job Information

Type:

 

 

Lightolier a Genlyte company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710

We reserve the right to change details of design, materials and finish.

© 2006 a Genlyte company

Section 5/Folio M32-21

Page 2
Image 2
Lightolier H9S1GLR254 Page 2 of, Ordering Information, Options/Accessories, Specifications continued, Folio M32-21