15 QUANTIZE
The QUANTIZE button is used to correct the timing of notes to any desired beat value. QUANTIZE only moves note events, and does not alter controllers, pitch bend, after touch, program change, and system exclusive information. While holding down the QUANTIZE button in part mode, the most recently recorded track will be lit, and the display will read:
The 10 quantize choices are 1/2, 1/4, 1/6, 1/8, 1/12, 1/16, 1/24, 1/32, 1/48, 1/64. The +/- buttons or the keypad can be used to scroll through the choices. The keypad buttons
This display remains until the RECORD button is released, which then returns the sequencer to its previous quantize display. The quantization process changes the start point of each note to the nearest quantize beat, but leaves the note release point where it was, which changes the actual note duration. Other quantizing options can be selected by using the page up and page down buttons. Pressing the page up button scrolls through the following choices:
If RECORD is pressed with QUANTIZE NOTE START & END being displayed, the release times of the notes will also be quantized to the selected quantize beat. If NOTE END is selected, only the release times of the notes will be quantized. If KEEP DURATION is selected, a note's duration will remain constant, i.e., if the start of a note is moved 1/16 note ahead, the release will also move 1/16 ahead.
In SONG mode, the QUANTIZE button is used to select an amount of clock offset for each track in a song. These offsets are global settings used by all songs, and do not affect the individual parts directly. The purpose of this feature is to allow the user to compensate for MIDI delays, and sound devices with slow attack times. While holding the QUANTIZE button in SONG mode, the first track LED will light, all others will be off, and the display will read as follows:
The value can be set from