EM-70 PLASTER/MORTAR MIXER — RULES FOR SAFE OPERATION

ALWAYS stop the engine before servicing, adding fuel and oil.

NEVER run engine without air filter. Severe engine may occur.

ALWAYS service air cleaner frequently to prevent carburetor malfunction.

ALWAYS be sure the operator is familiar with proper safety precautions and operations techniques before using mixer.

ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children.

DO NOT operate this equipment unless all guards and safety devices are attached and in place.

CAUTION must be exercised while servicing this equipment. Rotating and moving parts can cause injury if contacted.

When towing, an adequate safety chain must be fastened to the frame.See Towing Guidelines section in this manual.

Keep all inexperienced and unauthorized people away from the equipment at all times.

Unauthorized equipment modifications will void all warranties.

Check all fasteners periodically for tightness. Also check towing tongue bolt, lock nut and wheel lug nuts for wear.

Stop the engine and disconnect the spark plug before allowing anybody’s hands in the mixing drum.

NEVER pour or spray water over the engine or electric motor.

TRANSPORTING

ALWAYS shutdown engine before transporting.

Tighten fuel tank cap securely and close fuel cock to prevent fuel from spilling.

Drain fuel when transporting mixer over long distances or bad roads.

MAINTENANCE

NEVER lubricate components or attempt service on a running mixer.

ALWAYS allow the mixer a proper amount of time to cool before servicing.

Keep the mixer in proper running condition.

Fix damage to the mixer immediately and always replace broken parts.

Dispose of hazardous waste properly. Examples of potentially hazardous waste are used motor oil, fuel and fuel filters.

DO NOT use food or plastic containers to dispose of hazardous waste.

EMERGENCIES

ALWAYS know the location of the nearest fire extinguisher and first aid kit.

 

WARNING

Stand Clear of the

 

Mixer when in use

 

 

 

Always stand clear of the dump handle when the mixer is in operation. Any binding of material between the mixer blades and the drum will cause the drum handle to quickly move and could cause bodily harm.

Depending on type of mixer, test the ON/OFF switch for either the gasoline engine or electric motor before operating. The purpose of these switches is to shut down the engine or motor of the mixer.

Refer to the HONDA Engine Owner's Manual for engine technical questions or information recommended by Multiquip for this equipment. Damage to the equipment and/or injury to user may result.

In emergencies always know the location of the nearest phone or keep a phone on the job site. Also know the phone numbers of the nearest ambulance, doctor and fire department. This information will be invaluable in the case of an emergency.

EM-70 PLASTER/MORTAR MIXER — OPERATION MANUAL — REV. #1 (008/10/04) — PAGE 11

Page 11
Image 11
Multiquip EM-70S, EM-70P manual Never pour or spray water over the engine or electric motor, Stand Clear, Mixer when in use

EM-70S, EM-70P specifications

The Multiquip EM-70P and EM-70S are two robust and versatile electric generators designed to provide reliable power for various applications, ranging from construction sites to special events. Both models are renowned for their performance, durability, and efficiency, catering to the needs of contractors, event organizers, and outdoor enthusiasts alike.

One of the standout features of the EM-70P and EM-70S is their powerful engine. The EM-70P is equipped with a 7,000-watt gasoline engine, while the EM-70S comes with a 7,000-watt propane engine. This dual-fuel capability of the EM-70S not only enhances flexibility but also promotes cleaner and more efficient energy consumption. Both generators feature a heavy-duty steel frame that ensures maximum durability and protection against the rigors of job sites.

Technologically, these generators are designed with advanced noise reduction features. The low-noise operation makes them suitable for use in noise-sensitive environments, such as residential areas and events, allowing users to work or host gatherings without disturbing neighbors. Additionally, the EM-70P and EM-70S are equipped with an easy-to-read control panel, featuring circuit breakers and outlets that include multiple 120V and 240V options, ensuring compatibility with a wide range of tools and equipment.

Another notable characteristic of the EM-70P and EM-70S is their portability. Both models come with sturdy wheels and a foldable handle, making them easy to transport on job sites or during events. Their compact size does not compromise power output, as they can easily handle the demands of multiple tools and devices simultaneously.

Safety is also prioritized in the design of these generators. They feature a low-oil shutdown system which automatically turns off the engine when oil levels are critically low, preventing potential damage. Furthermore, the generators are designed to withstand harsh weather conditions, providing peace of mind to users who require dependable power in any environment.

In summary, the Multiquip EM-70P and EM-70S generators combine powerful performance, noise-reduction technology, user-friendly controls, and safety features. Whether you need a reliable power source for construction, outdoor events, or emergency backup, these generators present an ideal solution that meets diverse power needs efficiently and effectively.