EM-70 PLASTER/MORTAR MIXER — OPERATION MANUAL — REV. #1 (008/10/04) — PAGE 19
SEZISDROCNOISNETXEDEDNEMMOCER.6ELBAT
ledoMrotoMegatloV .tf05
)m42.51(
.tf57
)m68.22(
.tf001
)m84.03(
.tf002
)m69
.06(
07-ME
)cirtcelE( PH5.1 51121.oN01.oN8.oN6.oN
03241.oN21.oN21.oN8.oN
The motor supplied is wired for 115 VAC grounded operation.
Make certain that the correct size grounded (3-wires)
extension cord is used. See Table 6.
Motors can burn out when the line voltage falls 5% below
the voltage rating of the motor. Failure to use proper voltage
will cause the motor to overheat and actuate the overload
switch.
If overload protection should actuate because of improper
voltage or any other malfunction, turn the main switch on
the motor to the OFF position and correct the problem, press
the reset switch button, and turn the main switch to the ON
position.
Electric Motor Voltage Switch
1.
ALWAYS
make certain the motor switch is OFF and
the power cord has been disconnected from the power
source.
2. Remove the voltage lock-out bolt

(Figure 7). Change
the position of the

voltage change toggle switch

from
115 VAC to 230 VAC. The mixer is factory wired for 115
VAC operation.
3. Replace the voltage lock-out bolt.
EM-70 PLASTER/MORTAR MIXER — ELECTRIC MOTOR
NOTE

Important!,

when changing the input
voltage to the motor from 115 to 230
VAC the

plug

on the motor power
cord must also be changed. See
Table 4