| Architectural Decorative IS:CCLPS602P |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
Page 1 of 4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Instruction Sheet for Assembly and Installation |
Read and understand these instructions before installing luminaire
This luminaire is intended for installation in accordance with the National Electrical Code and local regulations. To assure full compliance with local codes and regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
Getting Started
CCLPS602P is a compact power/data supply for indoor installations. CCLPS602P provides power and data to Lightolier concealed color lighting product lines, and is available for DMX and Ethernet control options.
The “s” type of power supply provides additional features, such as base address and grouping of luminaire addresses, without the need for external components.
This instruction guide contains important information on installing and using your new CCLPS602P. Please read it carefully and save it for future reference.
Included In This Box
•Power/data supply
•US Grounded IEC Power Cord Set
•
•Instruction Sheet
Additional Items Needed
• Mounting hardware – 4 flat head screws M3.5 or #6
Scope of this Instruction Guide
The goal of this user guide is to explain the steps necessary to install CCLPS602P for DMX and Ethernet control to assure peak performance. Its intended use is for reference only, by persons who are fully qualified. This docu- ment should never be considered a substitute for any provisions of a regulation or state and/or local code.
Identification and Warnings of Safety Hazards
In accordance with ANSI
“Danger” Imminently hazardous situation which, if not avoided, will result in death or serious injury.
“Warning” Potentially hazardous situation which, if not avoided, could result in death or serious injury.
“Caution” Potentially hazardous situation which, if not avoided, may result in minor or moderate injury or property damage. Also used to alert against unsafe practices.
Ignoring a hazard will void any warranty.
Warning: Ensure that power is disconnected before installing, wiring, or servic- ing the CCLPS602P power supply.
Warning: The CCLPS602P power supply must be installed by a qualified profes- sional in accordance with NEC and relevant local codes.
Warning: Do not attempt to install or use CCLPS602P until you read and under- stand the installation instructions and safety labels.
Warning: Do not use CCLPS602P if power cables are damaged.
Warning: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to take adequate measures.
Caution: Ensure that CCLPS602P is securely attached, properly mounted, and free of excessive vibration.
Caution: Do not hot swap. Ensure the power supply is off before connecting or disconnecting luminaires.
Caution: Do not modify or alter CCLPS602P.
Note: The instructions and precautions set forth in this installation guide are not necessarily
Owner/User Responsibilities:
It is the responsibility of the contractor, installer, purchaser, owner, and user to install, maintain, and operate CCLPS602P in such a manner as to comply with all state and local laws, ordinances, regulations, and the American National Standards Institute Safety Code.
Note: CCLPS602P is shipped with a US IEC power cord. For international cus- tomers, use a
Note: Ensure the IEC inlet plug fits in the supplied lock. The lock may not accom- modate all plug styles.
Installation:
CCLPS602P must be installed by a qualified electrician in accordance with NEC and relevant local codes for power supplies. A power screwdriver is recom- mended for mounting the unit.
Mounting the Housing
•Select the location to mount the housing, keeping CCLPS602P within the maximum distance specified for your luminaire. Refer to your luminaire user guide for the cable run information.
Caution: CCLPS602P must be installed in a location that allows air to move freely. Packing insulation around the housing or mounting in a sealed location that raises ambient temperature above 122°F (50°C) may result in property dam- age and may void the warranty.
Note: Ensure that there is adequate space to make all connections to the front and rear of the unit.
•Mount the housing to a flat surface using four M3.5 or #6 flat head screws suitable for the mounting surface. Mounting slots are located on each end of the housing. (See Fig. 1.)
Note: Do not overtighten the mounting screws.
(21.2 cm) | Fig. 1 |
8.31" |
(5.7 cm)
2.25"
631 Airport Road, Fall River, MA 02720 • (508)