Whirlpool ACSIOZ ACS520 Installing Your Air Condiiioner, Meeting electrical requirements, In This

Models: ACSIOZ ACS520

1 26
Download 26 pages 27.56 Kb
Page 5
Image 5
Installing Your Air Condiiioner

Installing Your Air Condiiioner

In This

Section

 

 

 

 

 

 

PWP

 

 

PW

Mwttng m

nquirsmnb

-.. 5

installing in a sliding window

......5

PropsrIng fur instdauu4l

......5

ln.lallbIgin acrmont

window

.... 13

Proper installation of your air conditioner is important for proper operation and best cooling results. This section will tell you how to meet necessary electrical requirements and how to install your air conditioner properly into a sliding or casement style window. Please read these installation instructions, as well as the operating and care instructions, before installing your unit.

Meeting electrical requirements

OBSERVE ALL LOCAL CODES AND

ORDINANCES.

Elactrlul Shock and

Person81 Injury Hazard

lElectrical ground is required on this appliance.

lDO NOT modify the power supply cord plug. lf it does not fit the outlet, have a proper outlet installed by a qualified electrician.

lDO NOT have a fuse in the neutral or grounding circuit. A fuse in the neutral or grounding circuit could result in an electriial shock

lDO NOT use an extension cord with this appliance.

lCheck with a qualified electrician if you are in doubt as to whether the appliance is properly grounded.

Failure to follow these instructions could resutt in electrical shock, serious injury or death.

DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLY CORD GROUNDING PRONG.

NOTE: lf codes permit and a separate grounding wire is used, it is recommended that a qualified electrician determine that the grounding path is adequate and not interrupted by plastic, non- metallic gaskets or other insulating materials.

Receptacle wiring

Receptacle wiring should be a minimum of 14gauge. Use copper wire only. It is the respon- sibility of the consumer to provide proper and adequate receptacle wiring, installed by a qualified electrician. Observe the National Electrical Code and all local governing codes and ordinances.

Electrical requirements

A 115 volt (103.5 minimum, 126.5 maximum), 60 Hertz, AC only, 15 ampere fused electrical supply is required. A time delay fuse or time delay circuit breaker is also required. A separate circuit, sewing only this appliance, must be provided.

5

Page 5
Image 5
Whirlpool ACSIOZ ACS520 warranty Installing Your Air Condiiioner, Meeting electrical requirements, In This, Section