Lightolier manual Lighting Systems LP-23, Module Ordering Information, Features, Electrical

Models: LP-23

1 2
Download 2 pages 1.09 Kb
Page 1
Image 1
Lighting Systems LP-23

Lighting Systems LP-23

1BHFPG -JOFBS1FSG-ZUF DN 8BMM.PVOU-JHIU#JBY1FSh DN  /PNJOBM 4FDUJPO

8.00” (20.32cm)

2.50”

(6.35cm)

0.25”(0.64cm)

8.00” (20.32cm)0.25” (0.64cm)

Module Ordering Information

3.00”

PERF(7.62cm) 3.35" (8.51cm)

Half Scale

Style

Series

Lamps

Type

Length

Ballast

Options

LP

W

2

2 = 2 Lt Cross

B4 = 40w Biax

4 = 4-Foot

U = Uni-voltage

Blank = No Options

Section

B5 = 50w Biax

8 = 8-Foot

E = Emergency Pack

DS = Dual Switched

 

 

 

D1 = Dimming 120v

X4 = 4th through wire

 

 

 

D2 = Dimming 277v

 

Complete ordering instructions below.

Features

1.Housing: 18 gauge steel. Die-formed steel end cap with concealed access holes for through wiring. No exposed fasteners or hardware.

2.Lamping: Four FT40W or FT50W fluorescent lamp per 4-Foot section. Provided by others.

3.Reflector: Precision die-formed specular aluminum.

4.Diffuser: Opal Acrylic.

Electrical

Ballast is universal voltage, <10% THD, .88 ballast factor, instant start. 3 con- ductor, 18 gauge wire. Color-coded quick connectors allow ease of connection for joiner modules. For special circuiting consult factory. Factory installed ballast disconnect allows the ballast to be disconnected from and reconnected to incoming power under load without turning the entire circuit off.

Dimming: 120/277 VAC.

Emergency Battery Pack: 40 watt: 450 lumens @ 90 minutes.

Labels

UL, cUL and I.B.E.W.

Finish

Powder coated baked white enamel. Custom colors available, consult factory.

Options

Dual Switching: Order the DS option for separate row switching. DS option automatically ships with the X4 option included.

X4 Wire: Order X4 modules for remainder of the run when using dimming and/or switched emergency battery pack modules.

Emergency Circuiting: Special circuiting - consult factory.

Ordering Information

Individual Fixtures:

1.Order number of MODULES required.

2.Order one END SET per MODULE.

Continuous Rows:

1.Determine run length.

2.Order the appropriate number of MODULES for the complete run.

3.Order one END SET per run.

4.Order one JOINER CONNECTOR per MODULE in run minus one.

Job Information

Type:

Job Name:

Cat. No.:

Lamp(s):

Notes:

"JSQPSU3PBE'BMM3JWFS."t  t'BY  

We reserve the right to change details of design, materials and finish.

XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #

Page 1
Image 1
Lightolier manual Lighting Systems LP-23, Module Ordering Information, Features, Electrical, Labels, Finish, Options