Lighting Systems ST624-1
1BHFPG2
Performance
CANDLE POWER CURVE
180˚ | 175˚ | 165˚ | 155˚ | 145˚ | 135˚ |
|
|
|
|
| 125˚ |
|
|
|
|
| 115˚ |
|
|
|
|
| 105˚ |
|
|
|
|
| 95˚ |
0 |
|
|
|
| 90˚ |
200 |
|
|
|
| 85˚ |
400 |
|
|
|
|
|
600 |
|
|
|
| 75˚ |
|
|
|
|
| |
800 |
|
|
|
| 65˚ |
|
|
|
|
| |
000 |
|
|
|
|
|
200 |
|
|
|
| 55˚ |
400 |
|
|
|
| |
|
|
|
|
| |
0˚ | 5˚ | 15˚ | 25˚ | 35˚ | 45˚ |
REPORT NO: 0034FR |
| ||||
LAMPS: |
| ||||
LUMENS: 2900 |
|
| |||
EFFICIENCY: 76.2% |
|
CANDLE POWER SUMMARY
ZONE | 0 | 22 | 45 | 67 | 90 |
DEG. |
|
|
|
|
|
180 | 0 | 0 | 0 | 0 | 0 |
175 | 0 | 0 | 0 | 0 | 0 |
165 | 0 | 0 | 0 | 0 | 0 |
155 | 0 | 0 | 0 | 0 | 0 |
145 | 0 | 0 | 0 | 0 | 0 |
135 | 0 | 0 | 0 | 0 | 0 |
125 | 0 | 0 | 0 | 0 | 0 |
115 | 0 | 0 | 0 | 0 | 0 |
105 | 0 | 0 | 0 | 0 | 0 |
95 | 0 | 0 | 0 | 0 | 0 |
90 | 24 | 67 | 162 | 237 | 203 |
85 | 56 | 110 | 243 | 355 | 335 |
75 | 131 | 199 | 397 | 606 | 662 |
65 | 229 | 285 | 537 | 834 | 980 |
55 | 407 | 482 | 720 | 999 | 1165 |
45 | 656 | 721 | 903 | 1143 | 1277 |
35 | 900 | 950 | 1083 | 1259 | 1345 |
25 | 1124 | 1155 | 1247 | 1356 | 1397 |
15 | 1315 | 1323 | 1364 | 1415 | 1391 |
5 | 1444 | 1434 | 1431 | 1434 | 1394 |
0 | 1443 | 1443 | 1443 | 1443 | 1443 |
|
|
| COEFFICIENTS OF UTILIZATION |
|
| |||||
|
| % EFFECTIVE CEILING CAVITY REFLECTANCE |
| |||||||
|
|
| 80 |
|
| 70 |
|
| 50 |
|
|
|
|
| % WALL REFLECTANCE |
|
| ||||
|
| 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 |
| 0 | 91 | 91 | 91 | 89 | 89 | 89 | 85 | 85 | 85 |
RATIO | 1 | 78 | 74 | 71 | 76 | 73 | 70 | 73 | 70 | 68 |
2 | 68 | 62 | 58 | 66 | 61 | 57 | 63 | 59 | 56 | |
CAVITY | 3 | 60 | 53 | 48 | 58 | 52 | 48 | 56 | 51 | 47 |
4 | 53 | 46 | 41 | 52 | 46 | 40 | 50 | 44 | 40 | |
| 5 | 47 | 40 | 34 | 46 | 39 | 34 | 44 | 38 | 34 |
ROOM | 6 | 42 | 35 | 30 | 41 | 34 | 29 | 40 | 34 | 29 |
8 | 34 | 27 | 22 | 33 | 27 | 22 | 32 | 26 | 22 | |
| 7 | 37 | 31 | 26 | 37 | 30 | 26 | 36 | 30 | 26 |
| 9 | 30 | 24 | 19 | 30 | 24 | 19 | 29 | 23 | 19 |
| 10 | 28 | 21 | 17 | 27 | 21 | 17 | 26 | 21 | 17 |
|
|
| 20% FLOOR CAVITY REFLECTANCE |
| ||||||
|
|
| ZONAL LUMENS AND PERCENTAGES |
| ||||||
| ZONE | LUMENS % LAMP |
| % LUMINAIRE | ||||||
|
| 4418 |
| 76.2 |
|
| 100.00 |
| ||
|
| 0 |
| .00 |
|
| 0.00 |
| ||
|
| 4418 |
| 76.2 |
|
| 100.00 |
| ||
|
|
|
| **Efficiency = 76.2%** |
|
|
|
Quick Calculators and Mounting Accessories
OAH
Single Stem Chrome
S12 = 12" (30.48cm) OAH
S18 = 18" (45.72cm) OAH
S24 = 24" (60.96cm) OAH
Add WH for white stem
Fixture Lengths & Mounting Locations and Sample Run
OAH
Cable Assemblies:
C36 (cable only),
CC36 (cable/straight cord feed) CCC36 (cable/coiled cord feed)
Joiner Fixture
48" (121.92cm)
End Fixture
49" (124.46cm)
|
|
| 48" (121.92cm) |
|
|
|
| 48" (121.92cm) |
|
|
|
| 48" (121.92cm) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Single Stem or Cable |
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
| Power Feed Stem or Cable Cord |
| ||||||
|
|
| 49" (124.46cm) End |
| 48" (121.92cm) Joiner |
|
| 49" (124.46cm) End |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Note: Minimum run
Order one stem or cable per module and one stem or cable per run.
Job Information | Type: |
"JSQPSU3PBE'BMM3JWFS."t t'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt $