Gardena 7632, WP 1800, 7631 Storing your Garden Spring Pump, Accessories, Technical Data, Cleaning

Models: 7631 ART 7630 7632 WP 1200 WP 600

1 6
Download 6 pages 18.13 Kb
Page 3
Image 3
4. Storing your Garden Spring Pump

4. Storing your Garden Spring Pump

CAUTION!

Work on the electrical parts must only be carried out by

 

 

GARDENA Service Centres.

 

 

Storage:

GB

Disposal:

(in accordance with RL2002/96/EC)

The pump should be stored out of the reach of children.

1.Before the frosty season begins, take the pump out of the pond and clean it.

2.To avoid difficulties when starting up in the spring, we recom- mend storing the pump in a frost-free location in a container filled with water. The mains plug must not be submerged.

The product must not be added to normal household waste. It must be disposed of properly.

If any other faults arise, please contact GARDENA Service.

7. Accessories

GARDENA Underwater lights

Illumination of garden springs or objects

art. 7952

UL 20 / UL 20 S Set

in / on the pond.

art. 7958

 

 

 

GARDENA radio control set

Start water features and lighting from

art. 7874

 

the terrace or your living room.

8. Technical Data

GB

5. Cleaning

WP 600 (art. 7630)

WP 1200 (art. 7631)

WP 1800 (art. 7632)

Mains voltage/mains frequency 230 V AC / 50 Hz

230 V AC / 50 Hz

230 V AC / 50 Hz

Cleaning the pump:

3

8

CAUTION! Electric shock !

Risk of injury due to mains electricity.

vBefore cleaning the pump, unplug the it from the mains.

1.Remove the filter housing 3 from the motor housing 6, and clean it.

2.Turn the pump inlet 5 anticlockwise and pull it vertically off the motor housing 6 (bayonet socket).

3.Take the impeller 8 out of the motor housing 6 and clean it.

4.Push the cleaned impeller 8 back into the motor housing 6.

5.Push the pump inlet 5 vertically on to the motor housing 6 and tighten it clockwise. (If the pump is to suck from under- neath, the thread must face downwards).

Rated power

8 W

16 W

30 W

Power cable

10 m; H05-RN-F

10 m; H05-RN-F

10 m; H05-RN-F

 

 

 

 

Flow

600 l/h

1200 l/h

1800 l/h

 

 

 

 

Max. delivery head

1,2 m

1,6 m

2,0 m

 

 

 

 

Max. submersion depth

1 m

1 m

1 m

 

 

 

 

Pump connection

G 1/2

G 1/2

G 1/2

 

 

 

 

Media temperature

4 °C – 35 °C

4 °C – 35 °C

4 °C – 35 °C

9. Service / Guarantee

Guarantee

GARDENA guarantees this product for 3 years (from date of

5

6

6. Push the filter housing 3 back on to the motor housing 6.

6. Trouble-shooting

CAUTION! Electric shock!

Risk of injury due to mains electricity.

vBefore fault-finding, unplug the pump at the mains.

Fault

Possible cause

Remedy

The pump delivers no water

Mains plug not plugged in.

v Plug in mains plug.

 

 

 

 

Impeller unit is blocked.

v Clean pump.

 

 

 

 

Impeller running in the wrong

v Disconnect from the mains

 

direction due to insufficient water.

and top up with water.

 

 

 

 

Pump installed out of water

v Fill the inlet hose with water.

 

and not filled.

 

 

 

 

The pump delivers a reduced

Filter housing dirty.

v Clean filter housing.

water flow

 

 

purchase). This guarantee covers all serious defects of the unit

that can be proved to be material or manufacturing faults.

Under warranty we will either replace the unit or repair it free of

charge if the following conditions apply:

The unit must have been handled properly and in keeping with

the requirements of the User’s Manual.

• Neither the purchaser or a non-authorised third party have

attempted to repair the unit.

The feed impeller is a wearing part and is not covered by the

warranty.

This manufacturer’s guarantee does not affect the user’s existing

warranty claims against the dealer/ seller.

If you have any problems with your Fountain Pump Set,

please contact our Service or return the defective unit together

with a short description of the problem – in case of guarantee,

with a copy of the receipt – postage paid to one of the

GARDENA Service Centres listed on the back of this leaflet.

10

11

Page 3
Image 3
Gardena 7632 Storing your Garden Spring Pump, Accessories, Technical Data, Cleaning, Service / Guarantee, Trouble-shooting