Lincoln 1600-000-A, 1601-000-A Reversing Conveyor Direction, Fuseholder - Replacement

Models: 1601-000-A 1600-000-A

1 24
Download 24 pages 25.82 Kb
Page 10
Image 10
REVERSING CONVEYOR DIRECTION.

REVERSING CONVEYOR DIRECTION.

A.Shut off power at oven switch.

B.Set conveyor reversing switch in the other position.

C.Turn oven “on” and check for proper operation.

FUSEHOLDER - REPLACEMENT

A.Remove appropriate control box cover.

B.Remove two (2) wires, note wire number and location.

C.Remove lock nut on back side of fuse holder and push out.

D.Reinstall in reverse order and check system operation.

GAS VALVE, DUAL SAFETY - REPLACEMENT

A.Remove appropriate control box cover.

B.Remove incoming gas line.

C.Remove screws from incoming nipple mounting bracket.

D.Remove incoming nipple.

E.Remove bypass tube assy.

F.Disconnect pipe union.

G.Disconnect wiring from control valve (four [4] push on connectors), make note of wire numbers and location for reinstallation.

H.Remove gas piping from old valve and install on new one.

I.Reassemble in reverse order and check system operation. Set manifold pressure on gas valve. Pressure should be 3.5 in W.C. Nat., 10 in W.C. L.P.

NOTE: Check all gas line fittings for leaks, check and adjust manifold pressure.

TEMPERATURE REGULATING VALVE - REPLACEMENT

A.Remove appropriate control box cover

B.Remove bypass tube assy.

C.Remove four (4) nuts from burner orifice bracket.

D.Disconnect pipe union.

E.Disconnect two (2) wires from valve and remove assembly.

F.Remove gas piping from old valve and install on new one.

G.Reassemble in reverse order and check system operation. NOTE: Check all gas line fittings for leaks and insure valve gas flow is in proper direction .

10

Low Profile – 1600 Series Advantage Digital Service Manual – Domestic

Page 10
Image 10
Lincoln 1600-000-A Reversing Conveyor Direction, Fuseholder - Replacement, Gas Valve, Dual Safety - Replacement