NOTE: When checking components on left side of oven, be sure to check for proper connections in power connector, (marked P.C. on schematic diagram) located inside motor cover.

SYMPTOM

POSSIBLE CAUSE

EVALUATION

Oven fan will not run

Incoming power

Check circuit breakers, reset if required. Check power plug to be

 

supply

sure it is firmly in receptacle. Measure the incoming voltage. Call

 

 

power co. if needed.

 

Power switch

Check continuity between switch terminals. Replace switch as

 

 

needed.

 

Fuse, 10 Amp

Check, replace if necessary.

 

Fuse holder

Check, replace if necessary.

 

Fuse, 3 Amp

Check, replace if necessary.

 

Fuse holder

Check, replace if necessary.

 

Hi-limit thermostat(s),

Check for voltage on both sides of the switch. Terminals are

 

control box

normally closed. If open, reset and test oven for proper operation.

 

 

If thermostat will not hold, and control box temperature is not

 

 

exceeding 140°F (60°C), replace thermostat

 

Relay, oven power

Check for 120 VAC to the relay coil. If voltage is not present,

 

 

Trace wiring back to the hi-limit thermostat. If voltage is present,

 

 

check to insure contacts are closing. Check for 120 VAC supplied

 

 

to terminal #2 of the relay. If voltage is not present at terminal #2,

 

 

trace wiring back to the 10 Amp fuse. Replace relay as needed.

 

Motor, main fan

Check for opens, shorts or grounds. WITH POWER OFF: turn

 

 

fan blade to check for locked rotor.

 

Capacitor

Check for shorts or grounds. WARNING: Capacitor has a stored

 

 

charge, discharge before testing.

No control box cooling

Incoming power

Check circuit breakers, reset if required. Check power plug to be

 

 

sure it is firmly in receptacle. Call power co. if needed.

 

Power switch

Check continuity between switch terminals. Replace switch as

 

 

needed.

 

Fuse, 3 Amp

Check, replace if necessary.

 

Fuse holder

Check, replace if necessary.

 

Hi-limit thermostat(s),

Check for voltage on both sides of the switch. Terminals are

 

control box

normally closed. If open, reset and test oven for proper

 

 

operation. If thermostat will not hold and control box temperature

 

 

is not exceeding 140°F (60°C), replace thermostat.

 

Cooling fan(s)

120 VAC should now be at the fan motor. If voltage is not

 

 

present, trace wiring back to hi-limit thermostat. Check motor for

 

 

opens, shorts or grounds. WITH POWER OFF: Check for locked

 

 

rotor.

No automatic control box

Incoming power

Check circuit breakers, reset if required. Check power plug to be

cooling

supply

sure it is firmly in receptacle. Call power co. if required.

 

Cooling fan

Check the cooling fan thermostat. (thermostat closes at 120°F

 

thermostat(s)

°

 

 

and opens at 100 F) With the cooling fan thermostat preheated,

 

 

check for continuity. If switch is open, replace thermostat.

 

Fuse, 3 Amp

Check, replace if necessary.

 

Fuse holder

Check, replace if necessary.

 

Hi-limit thermostat(s)

Check for voltage on both sides of switch. Terminals are

 

control box

normally closed. If open, reset and test oven for proper

 

 

operation. If thermostat will not hold, and control box