TROUBLESHOOTING GUIDE
GAS OVENS
MODEL | NATURAL GAS | 120 VAC. | 60 HZ. | 1 PHASE |
MODEL | LP GAS | 120 VAC. | 60 HZ. | 1 PHASE |
NOTE: When checking components on left side of oven, be sure to check for proper connections in power connector, (marked P.C. on schematic diagram) located inside motor cover.
SYMPTOM | POSSIBLE CAUSE | EVALUATION |
Oven fan will not run | Incoming power | Check circuit breakers, reset if required. Check power plug to be |
| supply | sure it is firmly in receptacle. Measure the incoming voltage. Call |
|
| power co. if needed. |
| Power switch | Check continuity between switch terminals. Replace switch as |
|
| needed. |
| Fuse, 10 Amp | Check, replace if necessary. |
| Fuse holder | Check, replace if necessary. |
| Fuse, 3 Amp | Check, replace if necessary. |
| Fuse holder | Check, replace if necessary. |
| Check for voltage on both sides of the switch. Terminals are | |
| control box | normally closed. If open, reset and test oven for proper operation. |
|
| If thermostat will not hold, and control box temperature is not |
|
| exceeding 140°F (60°C), replace thermostat |
| Relay, oven power | Check for 120 VAC to the relay coil. If voltage is not present, |
|
| Trace wiring back to the |
|
| check to insure contacts are closing. Check for 120 VAC supplied |
|
| to terminal #2 of the relay. If voltage is not present at terminal #2, |
|
| trace wiring back to the 10 Amp fuse. Replace relay as needed. |
| Motor, main fan | Check for opens, shorts or grounds. WITH POWER OFF: turn |
|
| fan blade to check for locked rotor. |
| Capacitor | Check for shorts or grounds. WARNING: Capacitor has a stored |
|
| charge, discharge before testing. |
No control box cooling | Incoming power | Check circuit breakers, reset if required. Check power plug to be |
|
| sure it is firmly in receptacle. Call power co. if needed. |
| Power switch | Check continuity between switch terminals. Replace switch as |
|
| needed. |
| Fuse, 3 Amp | Check, replace if necessary. |
| Fuse holder | Check, replace if necessary. |
| Check for voltage on both sides of the switch. Terminals are | |
| control box | normally closed. If open, reset and test oven for proper |
|
| operation. If thermostat will not hold and control box temperature |
|
| is not exceeding 140°F (60°C), replace thermostat. |
| Cooling fan(s) | 120 VAC should now be at the fan motor. If voltage is not |
|
| present, trace wiring back to |
|
| opens, shorts or grounds. WITH POWER OFF: Check for locked |
|
| rotor. |
No automatic control box | Incoming power | Check circuit breakers, reset if required. Check power plug to be |
cooling | supply | sure it is firmly in receptacle. Call power co. if required. |
| Cooling fan | Check the cooling fan thermostat. (thermostat closes at 120°F |
| thermostat(s) | ° |
|
| and opens at 100 F) With the cooling fan thermostat preheated, |
|
| check for continuity. If switch is open, replace thermostat. |
| Fuse, 3 Amp | Check, replace if necessary. |
| Fuse holder | Check, replace if necessary. |
| Check for voltage on both sides of switch. Terminals are | |
| control box | normally closed. If open, reset and test oven for proper |
|
| operation. If thermostat will not hold, and control box |