Key Controls

A CLOSER LOOK

Key Controls

Press to select procedure.

Dual Procedure/Memory Panel Option shown for Power Feed 10M Single Bench Model

The Dual Procedure/Memory Panel is standard equipment on Power Feed 10M Dual Bench Models and optional on Single Bench Models. This panel performs three functions: weld procedure selection, feed head selection and memory saving/recall. There are two procedure memories (A and B) and six user memories (1- 6) for each feed head to store your favorite settings.

Synergic Control CV Voltage Display

Synergic Control CV programs feature an ideal voltage best suited for most procedures. Use this voltage as a starting point for the weld procedure and adjust if needed based on personal preference. When the voltage knob is rotated, the display will show an upper or lower bar indicating that the voltage is above or below the ideal voltage.

Above ideal voltage (upper bar display)

At ideal voltage (no bar displayed)

Below ideal voltage (lower bar display)

Front:

1.Bright, high intensity large digital display of voltage and wire feed speed.

2.Dual Procedure Memory Panel - retain settings in memory to switch back and forth between two different weld procedures. Use any of six memories to store your favorite settings.

3.MSP4 Panel (see page 2).

4.2-Step/4-Step Trigger Switch — change from simple ON/OFF in 2-step position to trigger interlock in 4-step position.

5.ArcLink status Lighted Electronic Display.

6.Cold Inch/Gas Purge switch — feed wire through a gun, or purge gas line to set flow rate all with welding output off for safety and gas savings.

7.Water Cooler Kit Connection (Optional).

8.5-pin amphenol gun trigger connector.

Back:

1.Access Panel — remove to change DIP settings.

2.Shielding Gas Inlet — industry standard 5/8 - 18 CGA connection.

3.Spool Gun/Push-Pull Gun Connector — for connecting Python®, CobraMAX™ and Prince XL® guns.

4.Remote/Foot Amptrol Connector for TIG welding (Optional).

5.ArcLink Control Cable Connector.

6.Water Cooler Connector (Optional).

QUALITY AND RELIABILITY

Rugged steel case, sturdy controls and quality meter displays.

Ambient temperature range for operation (-10° C to +40° C) and storage (-40° C to +40° C).

Designed to resist electrical noise.

Conforms to cCSAUL / CE Standards:

C22.2 No. 60, UL551, EN 60974-5, EN 50199.

Meets IP21S rating.

PC Boards are potted, trayed and filled with epoxy for ultimate protection in harsh environments.

Three-year Lincoln warranty on parts and labor.

Manufactured under a quality system certified to ISO 9001 requirements and ISO 14001 environmental standards.

Printed circuit boards are trayed, potted and filled with epoxy to provide a robust environmental shield.

Power Feed 10M

[3]

www.lincolnelectric.com

Page 3
Image 3
Lincoln Electric dimensions Quality And Reliability, Key Controls, Front, Back, Power Feed 10M, A Closer Look