A-7
INSTALLATION
LN™-25 PIPE
A-7
CV Power Source with Twist-Mate Connectors and
Remote/Local Switch. (See Figure A.8)
Place CV/CC switch in the feeder in the "CV" position.
Work clip
Work
Electrode
LN™-25 PIPE
CV-305
V350-Pro
Work clip
Work
Electrode
LN™-25 PIPE
CV-305
V350-Pro
FIGURE A.8
K#
K2614-5
KP1695-XX
KP1696-XX
KP1697-XX
See Magnum Literature
K1841
Description
LN™-25 PIPE
Drive Roll Kit
Welding Gun
CV power Source
Welding Cables
CV Power Source with Twist-Mate Connectors and
no Remote/Local Switch. (See Figure A.9)
Place CV/CC switch in the feeder in the "CV" position.
Work clip
Work
Electrode
Jumper
LN™-25 PIPE
CV-250
CV-300
Work clip
Work
Electrode
Jumper
LN™-25 PIPE
CV-250
CV-300
FIGURE A.9
K#
K2614-5
KP1695-XX
KP1696-XX
KP1697-XX
See Magnum Literature
K1841-
K852-95
K484
Description
LN™-25 PIPE
Drive Roll Kit
Welding Gun
CV power Source
Welding Cables
Twist-Mate Cable Plug
Jumper Plug kit